{"title":"隐式耦合机电与电磁瞬变分析的等效模型","authors":"Xu Zhang, A. Flueck, S. Abhyankar","doi":"10.1109/NAPS.2014.6965477","DOIUrl":null,"url":null,"abstract":"This paper presents two sets of equivalent models for implicitly-coupled electromechanical and electromagnetic transient analysis: a Thevenin equivalent of the electromechanical network and a Norton equivalent of the electromechanical network. Due to the possible lack of voltage reference in the electromagnetic network, the Norton equivalent of the electromechanical network is not as robust as the Thevenin equivalent in implicitly-coupled transient simulation. Results demonstrating the advantage of the implicitly-coupled electromechanical and electromagnetic simulator with Thevenin equivalent of the electromechanical network are presented for a 3 bus test system.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Equivalent models for implicitly-coupled electromechanical and electromagnetic transient analysis\",\"authors\":\"Xu Zhang, A. Flueck, S. Abhyankar\",\"doi\":\"10.1109/NAPS.2014.6965477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents two sets of equivalent models for implicitly-coupled electromechanical and electromagnetic transient analysis: a Thevenin equivalent of the electromechanical network and a Norton equivalent of the electromechanical network. Due to the possible lack of voltage reference in the electromagnetic network, the Norton equivalent of the electromechanical network is not as robust as the Thevenin equivalent in implicitly-coupled transient simulation. Results demonstrating the advantage of the implicitly-coupled electromechanical and electromagnetic simulator with Thevenin equivalent of the electromechanical network are presented for a 3 bus test system.\",\"PeriodicalId\":421766,\"journal\":{\"name\":\"2014 North American Power Symposium (NAPS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2014.6965477\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Equivalent models for implicitly-coupled electromechanical and electromagnetic transient analysis
This paper presents two sets of equivalent models for implicitly-coupled electromechanical and electromagnetic transient analysis: a Thevenin equivalent of the electromechanical network and a Norton equivalent of the electromechanical network. Due to the possible lack of voltage reference in the electromagnetic network, the Norton equivalent of the electromechanical network is not as robust as the Thevenin equivalent in implicitly-coupled transient simulation. Results demonstrating the advantage of the implicitly-coupled electromechanical and electromagnetic simulator with Thevenin equivalent of the electromechanical network are presented for a 3 bus test system.