{"title":"醛/加压固定犬颈动脉固定率及尺寸变化的定量测定。","authors":"R G Kratky, D K Lo, M R Roach","doi":"10.1159/000158885","DOIUrl":null,"url":null,"abstract":"<p><p>Excised canine carotid arteries held at constant physiologic length were cycled from -13 to +27 kPa with a constant-flow infusion pump, and the pressure-volume curves were recorded. The change in diameter on reducing the pressure from 16 to 0 kPa was determined and the strain of recoil [(diameter16--diameter0)/diameter16] calculated. Diameter recoil was reduced from 51% (fresh tissue) to 5% after 3 h pressure fixation in 4% formaldehyde and to 9% after 15 min in 2% glutaraldehyde with little further change. Lengthwise recoil was reduced from 37 to 10% after 5 min in 2% glutaraldehyde. Photographs were taken to measure outer diameter during pressure fixation. There was no change in diameter in either fixative from the first minute up to 3 days at the constant pressure of 16 kPa.</p>","PeriodicalId":9009,"journal":{"name":"Blood vessels","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000158885","citationCount":"17","resultStr":"{\"title\":\"Quantitative measurement of fixation rate and dimension changes in the aldehyde/pressure-fixed canine carotid artery.\",\"authors\":\"R G Kratky, D K Lo, M R Roach\",\"doi\":\"10.1159/000158885\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Excised canine carotid arteries held at constant physiologic length were cycled from -13 to +27 kPa with a constant-flow infusion pump, and the pressure-volume curves were recorded. The change in diameter on reducing the pressure from 16 to 0 kPa was determined and the strain of recoil [(diameter16--diameter0)/diameter16] calculated. Diameter recoil was reduced from 51% (fresh tissue) to 5% after 3 h pressure fixation in 4% formaldehyde and to 9% after 15 min in 2% glutaraldehyde with little further change. Lengthwise recoil was reduced from 37 to 10% after 5 min in 2% glutaraldehyde. Photographs were taken to measure outer diameter during pressure fixation. There was no change in diameter in either fixative from the first minute up to 3 days at the constant pressure of 16 kPa.</p>\",\"PeriodicalId\":9009,\"journal\":{\"name\":\"Blood vessels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000158885\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood vessels\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000158885\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood vessels","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000158885","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quantitative measurement of fixation rate and dimension changes in the aldehyde/pressure-fixed canine carotid artery.
Excised canine carotid arteries held at constant physiologic length were cycled from -13 to +27 kPa with a constant-flow infusion pump, and the pressure-volume curves were recorded. The change in diameter on reducing the pressure from 16 to 0 kPa was determined and the strain of recoil [(diameter16--diameter0)/diameter16] calculated. Diameter recoil was reduced from 51% (fresh tissue) to 5% after 3 h pressure fixation in 4% formaldehyde and to 9% after 15 min in 2% glutaraldehyde with little further change. Lengthwise recoil was reduced from 37 to 10% after 5 min in 2% glutaraldehyde. Photographs were taken to measure outer diameter during pressure fixation. There was no change in diameter in either fixative from the first minute up to 3 days at the constant pressure of 16 kPa.