L. Michi, E. Carlini, T. B. Scirocco, G. Bruno, R. Gnudi, G. Pecoraro, C. Pisani
{"title":"VSC-HVDC系统交流传输仿真控制策略:控制系统最优整定的一般准则","authors":"L. Michi, E. Carlini, T. B. Scirocco, G. Bruno, R. Gnudi, G. Pecoraro, C. Pisani","doi":"10.1109/AEIT-HVDC.2019.8740356","DOIUrl":null,"url":null,"abstract":"AC Transmission Emulation Control Strategy is a promising way to control the ordered active power flow in a VSC-HVDC system as a function of the phase angle over the parallel AC interconnection. The main advantage of this strategy is that no direct operator active power set-point dispatch is needed: HVDC interconnection basically behaves like an alternating current (AC) transmission line characterized by a proper impedance. Despite the high-level control strategy seems relatively simple the choice of an appropriate set of parameters is essential in order to preserve system stability on wide and appropriate grid support in N-1 condition. In light of this need, the paper introduces general criteria to follow for optimal tuning of VSC-HVDC control system in AC Transmission Emulation Control mode. It can be considered as a general methodology that can assist TSO in selecting those parameters of VSC-HVDC control system in AC Transmission Emulation Control mode which mainly affect the HVDCs behaviour in the interconnected power systems.","PeriodicalId":186931,"journal":{"name":"2019 AEIT HVDC International Conference (AEIT HVDC)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"AC Transmission Emulation Control Strategy in VSC-HVDC systems: general criteria for optimal tuning of control system\",\"authors\":\"L. Michi, E. Carlini, T. B. Scirocco, G. Bruno, R. Gnudi, G. Pecoraro, C. Pisani\",\"doi\":\"10.1109/AEIT-HVDC.2019.8740356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"AC Transmission Emulation Control Strategy is a promising way to control the ordered active power flow in a VSC-HVDC system as a function of the phase angle over the parallel AC interconnection. The main advantage of this strategy is that no direct operator active power set-point dispatch is needed: HVDC interconnection basically behaves like an alternating current (AC) transmission line characterized by a proper impedance. Despite the high-level control strategy seems relatively simple the choice of an appropriate set of parameters is essential in order to preserve system stability on wide and appropriate grid support in N-1 condition. In light of this need, the paper introduces general criteria to follow for optimal tuning of VSC-HVDC control system in AC Transmission Emulation Control mode. It can be considered as a general methodology that can assist TSO in selecting those parameters of VSC-HVDC control system in AC Transmission Emulation Control mode which mainly affect the HVDCs behaviour in the interconnected power systems.\",\"PeriodicalId\":186931,\"journal\":{\"name\":\"2019 AEIT HVDC International Conference (AEIT HVDC)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 AEIT HVDC International Conference (AEIT HVDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEIT-HVDC.2019.8740356\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 AEIT HVDC International Conference (AEIT HVDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEIT-HVDC.2019.8740356","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
AC Transmission Emulation Control Strategy in VSC-HVDC systems: general criteria for optimal tuning of control system
AC Transmission Emulation Control Strategy is a promising way to control the ordered active power flow in a VSC-HVDC system as a function of the phase angle over the parallel AC interconnection. The main advantage of this strategy is that no direct operator active power set-point dispatch is needed: HVDC interconnection basically behaves like an alternating current (AC) transmission line characterized by a proper impedance. Despite the high-level control strategy seems relatively simple the choice of an appropriate set of parameters is essential in order to preserve system stability on wide and appropriate grid support in N-1 condition. In light of this need, the paper introduces general criteria to follow for optimal tuning of VSC-HVDC control system in AC Transmission Emulation Control mode. It can be considered as a general methodology that can assist TSO in selecting those parameters of VSC-HVDC control system in AC Transmission Emulation Control mode which mainly affect the HVDCs behaviour in the interconnected power systems.