{"title":"从雷电附着模型出发,分析了雷电防护中的网格法","authors":"L. Arevalo, V. Cooray","doi":"10.1109/ICLP.2016.7791431","DOIUrl":null,"url":null,"abstract":"Based on the well-known rolling sphere method, international standards recommend the location of the external lightning protection system of structures. The design of the external lightning protection system of structures of height of less than 60 m can be done by installing a mesh on top of a roof of the structure or by creating a mesh with wires at certain distance from the roof of the structure. The prospective downward leader current that the mesh can incept depends on the size of the mesh and the current magnitude is given as recommendation in the international standards. This paper analyses the relation prospective negative downward leader current vs. mesh size from a lightning attachment model. The model is applied to a perfectly grounded structure with maximum height of 50 m protected by two different external lightning protection systems recommended by the international standards. The results showed difference on magnitude of the prospective downward leader current the standards recommend and the ones obtained using the lightning attachment model for meshes of shorter size. Discrepancies concerning the minimum downward leader current that can be incepted by a mesh made by wires located at certain distance from the ground structure and a mesh located on top of the building are obtained.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"The mesh method in lightning protection analyzed from a lightning attachment model\",\"authors\":\"L. Arevalo, V. Cooray\",\"doi\":\"10.1109/ICLP.2016.7791431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the well-known rolling sphere method, international standards recommend the location of the external lightning protection system of structures. The design of the external lightning protection system of structures of height of less than 60 m can be done by installing a mesh on top of a roof of the structure or by creating a mesh with wires at certain distance from the roof of the structure. The prospective downward leader current that the mesh can incept depends on the size of the mesh and the current magnitude is given as recommendation in the international standards. This paper analyses the relation prospective negative downward leader current vs. mesh size from a lightning attachment model. The model is applied to a perfectly grounded structure with maximum height of 50 m protected by two different external lightning protection systems recommended by the international standards. The results showed difference on magnitude of the prospective downward leader current the standards recommend and the ones obtained using the lightning attachment model for meshes of shorter size. Discrepancies concerning the minimum downward leader current that can be incepted by a mesh made by wires located at certain distance from the ground structure and a mesh located on top of the building are obtained.\",\"PeriodicalId\":373744,\"journal\":{\"name\":\"2016 33rd International Conference on Lightning Protection (ICLP)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 33rd International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2016.7791431\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791431","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

国际标准以众所周知的滚球法为基础,推荐了结构物外部防雷系统的位置。高度小于60m的结构物外部防雷系统的设计,可以在结构物屋顶顶部安装网,也可以在离结构物屋顶一定距离处设置有导线的网。筛网能承受的预期下导电流取决于筛网的尺寸,目前的大小是国际标准中推荐的。本文从闪电依恋模型出发,分析了预期负向下先导电流与网眼尺寸的关系。该模型应用于一个最大高度为50 m的完美接地结构,该结构采用国际标准推荐的两种不同的外部防雷系统进行保护。结果表明,对于较短尺寸的网格,使用闪电附着模型得到的预期下导电流大小与标准推荐值存在差异。得到了距离地面结构一定距离的导线制成的网和位于建筑物顶部的网所能接收的最小向下先导电流的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The mesh method in lightning protection analyzed from a lightning attachment model
Based on the well-known rolling sphere method, international standards recommend the location of the external lightning protection system of structures. The design of the external lightning protection system of structures of height of less than 60 m can be done by installing a mesh on top of a roof of the structure or by creating a mesh with wires at certain distance from the roof of the structure. The prospective downward leader current that the mesh can incept depends on the size of the mesh and the current magnitude is given as recommendation in the international standards. This paper analyses the relation prospective negative downward leader current vs. mesh size from a lightning attachment model. The model is applied to a perfectly grounded structure with maximum height of 50 m protected by two different external lightning protection systems recommended by the international standards. The results showed difference on magnitude of the prospective downward leader current the standards recommend and the ones obtained using the lightning attachment model for meshes of shorter size. Discrepancies concerning the minimum downward leader current that can be incepted by a mesh made by wires located at certain distance from the ground structure and a mesh located on top of the building are obtained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and theoretical evaluation of aluminium deflection due to lightning strikes Degradation characteristics on MOV of surge arrester used for 6.6kV power distribution line Lightning protection of a temporary structure in open area Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid Research of influence pattern of lightning current on impulse characteristic of ground device for pole and tower
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1