P. Prempraneerach, M. Angle, J. Kirtley, G. Karniadakis, C. Chryssostomidis
{"title":"z源直流断路器的优化设计","authors":"P. Prempraneerach, M. Angle, J. Kirtley, G. Karniadakis, C. Chryssostomidis","doi":"10.1109/ESTS.2013.6523780","DOIUrl":null,"url":null,"abstract":"DC faults may cause severe disruptions in continuity of service to vital loads in a shipboard integrated power system, hence detection, isolation, and protection against such faults must be incorporated in both medium-voltage DC (MVDC) and low-voltage DC (LVDC) systems. Here we consider the effectiveness of existing z-source breakers and propose several new designs more appropriate for fault detection in MVDC and LVDC systems. In particular, we perform an optimization study that aims to minimize dissipation and weight and we identify the key parameters for use in MVDC and LVDC systems. Preliminary verification and validation studies are also included.","PeriodicalId":119318,"journal":{"name":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","volume":"120 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"28","resultStr":"{\"title\":\"Optimization of a z-source DC circuit breaker\",\"authors\":\"P. Prempraneerach, M. Angle, J. Kirtley, G. Karniadakis, C. Chryssostomidis\",\"doi\":\"10.1109/ESTS.2013.6523780\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"DC faults may cause severe disruptions in continuity of service to vital loads in a shipboard integrated power system, hence detection, isolation, and protection against such faults must be incorporated in both medium-voltage DC (MVDC) and low-voltage DC (LVDC) systems. Here we consider the effectiveness of existing z-source breakers and propose several new designs more appropriate for fault detection in MVDC and LVDC systems. In particular, we perform an optimization study that aims to minimize dissipation and weight and we identify the key parameters for use in MVDC and LVDC systems. Preliminary verification and validation studies are also included.\",\"PeriodicalId\":119318,\"journal\":{\"name\":\"2013 IEEE Electric Ship Technologies Symposium (ESTS)\",\"volume\":\"120 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"28\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Electric Ship Technologies Symposium (ESTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTS.2013.6523780\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2013.6523780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
DC faults may cause severe disruptions in continuity of service to vital loads in a shipboard integrated power system, hence detection, isolation, and protection against such faults must be incorporated in both medium-voltage DC (MVDC) and low-voltage DC (LVDC) systems. Here we consider the effectiveness of existing z-source breakers and propose several new designs more appropriate for fault detection in MVDC and LVDC systems. In particular, we perform an optimization study that aims to minimize dissipation and weight and we identify the key parameters for use in MVDC and LVDC systems. Preliminary verification and validation studies are also included.