Kholid Al Sulaimi, Wisnu Kartika, Kuat Supriyadi
{"title":"ANALISIS SUHU PADA ANALYZER INKUBATOR BAYI BERBASIS FORMULA MEAN","authors":"Kholid Al Sulaimi, Wisnu Kartika, Kuat Supriyadi","doi":"10.18196/MT.010101","DOIUrl":null,"url":null,"abstract":"Baby incubator is an equipment to keep the temperature stability of premature babies. Temperature is an important parameter. Therefore, its stability should be monitored based on the standard required by BPFK (Health Facilities Safety Center) hence the need for calibration. The writer aims to make a calibration tool for baby incubator temperature parameter with four measurement spots. The main sensor from the temperature parameter of incubator analyzer is LM35 as temperature sensor of T1, T2, T3, and T4. The range of temperature that can be detected is between 20.00 o C – 50.00 o C. The temperature inside the baby incubator has to be between 35.5 o C – 37 o C. The test was conducted in the baby incubator starting from 32 o C – 37 o C. The data was collected from the test point value on each temperature spot, the temperature comparison between TA modules used fluke temperature meter as comparison tool and the calibration of baby incubator. The output power for LM35 temperature sensor was done as much as ± 5 times. The biggest error value was found on T4 temperature sensor at ± 1.09762824% and at the temperature of 37 o C, while the smallest error value was found on T1 temperature sensor at ± 0.005633803% at the temperature of 35 o C. The measurement of baby incubator temperature calibration shows the margin of baby incubator temperature meter ± 1 o C at the temperature setting of 32 o C, 33 o C, and 34 o C.","PeriodicalId":441327,"journal":{"name":"Medika Teknika : Jurnal Teknik Elektromedik Indonesia","volume":"57 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medika Teknika : Jurnal Teknik Elektromedik Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18196/MT.010101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

婴儿保温箱是一种保持早产儿体温稳定的设备。温度是一个重要的参数。因此,应根据BPFK(卫生设施安全中心)要求的标准监测其稳定性,因此需要进行校准。研制了一种具有四个测量点的婴儿恒温箱温度参数校准工具。培养箱分析仪温度参数的主要传感器为LM35,作为T1、T2、T3、T4的温度传感器。温度能被探测到的范围在20.00 o C - 50.00 o C .婴儿孵化器内的温度必须在35.5 o 37 C - o C测试是在婴儿培养箱进行从32 o 37 C - o C的数据收集测试点值在每个温度点,温度比较TA模块使用侥幸温度计比较工具和婴儿培养箱的校准。LM35温度传感器输出功率达到±5倍。T4温度传感器在37℃时误差最大,误差值为±1.09762824%,T1温度传感器在35℃时误差最小,误差值为±0.005633803%。婴儿恒温箱温度校准测量显示,在32℃、33℃、34℃的温度设置下,婴儿恒温箱温度计的裕度为±1℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ANALISIS SUHU PADA ANALYZER INKUBATOR BAYI BERBASIS FORMULA MEAN
Baby incubator is an equipment to keep the temperature stability of premature babies. Temperature is an important parameter. Therefore, its stability should be monitored based on the standard required by BPFK (Health Facilities Safety Center) hence the need for calibration. The writer aims to make a calibration tool for baby incubator temperature parameter with four measurement spots. The main sensor from the temperature parameter of incubator analyzer is LM35 as temperature sensor of T1, T2, T3, and T4. The range of temperature that can be detected is between 20.00 o C – 50.00 o C. The temperature inside the baby incubator has to be between 35.5 o C – 37 o C. The test was conducted in the baby incubator starting from 32 o C – 37 o C. The data was collected from the test point value on each temperature spot, the temperature comparison between TA modules used fluke temperature meter as comparison tool and the calibration of baby incubator. The output power for LM35 temperature sensor was done as much as ± 5 times. The biggest error value was found on T4 temperature sensor at ± 1.09762824% and at the temperature of 37 o C, while the smallest error value was found on T1 temperature sensor at ± 0.005633803% at the temperature of 35 o C. The measurement of baby incubator temperature calibration shows the margin of baby incubator temperature meter ± 1 o C at the temperature setting of 32 o C, 33 o C, and 34 o C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Prototipe Lung Tumor e-mannequin untuk Pelatihan Keterampilan Fine Needle Aspiration Biopsy Analisis Pengaturan Faktor Eksposi Dosis Serap Pasien Menggunakan Piranha 557 Rancang Bangun Gergaji Plaster Gypsum Medis dengan Pengaturan Kecepatan Berbasis Mikrokontroler Prototype Alat Pengering Ikan Asin untuk Nelayan Berbasis IOT Rancang Bangun Sistem Informasi E-Commerce Handphone (Studi Kasus Raya Selluler Demak)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1