风电一体化动态线路评定系统的性能

J. G. Olazarri, A. Mazón, S. Rementeria, I. Albizu, E. Fernández
{"title":"风电一体化动态线路评定系统的性能","authors":"J. G. Olazarri, A. Mazón, S. Rementeria, I. Albizu, E. Fernández","doi":"10.1109/ICCEP.2015.7177548","DOIUrl":null,"url":null,"abstract":"Different dynamic line rating systems have been developed in order to monitor lines and calculate the actual line rating. In this paper weather, conductor temperature and conductor tension based systems are analyzed. Measurements in two pilot lines were taken. One of them is the 66 kV evacuation line of a wind farm whereas, the other one is a 30 kV distribution line. In the analysis, actual rating values are calculated with the measurements of each system. Due to the fact that DLR results of the conductor temperature and conductor tension systems are inaccurate when differences between conductor temperature and ambient temperature are low, the analysis is made at different temperature ranges.","PeriodicalId":423870,"journal":{"name":"2015 International Conference on Clean Electrical Power (ICCEP)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Performance of dynamic line rating systems for wind integration\",\"authors\":\"J. G. Olazarri, A. Mazón, S. Rementeria, I. Albizu, E. Fernández\",\"doi\":\"10.1109/ICCEP.2015.7177548\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Different dynamic line rating systems have been developed in order to monitor lines and calculate the actual line rating. In this paper weather, conductor temperature and conductor tension based systems are analyzed. Measurements in two pilot lines were taken. One of them is the 66 kV evacuation line of a wind farm whereas, the other one is a 30 kV distribution line. In the analysis, actual rating values are calculated with the measurements of each system. Due to the fact that DLR results of the conductor temperature and conductor tension systems are inaccurate when differences between conductor temperature and ambient temperature are low, the analysis is made at different temperature ranges.\",\"PeriodicalId\":423870,\"journal\":{\"name\":\"2015 International Conference on Clean Electrical Power (ICCEP)\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Clean Electrical Power (ICCEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCEP.2015.7177548\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2015.7177548","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

为了监测线路并计算实际线路额定值,人们开发了不同的动态线路额定值系统。本文分析了基于天气、导体温度和导体张力的系统。在两条试验线上进行了测量。其中一条是66千伏的风电场疏散线路,另一条是30千伏的配电线路。在分析中,根据每个系统的测量值计算出实际额定值。由于导体温度与环境温度差较小时,导体温度和导体张力系统的DLR结果不准确,因此在不同的温度范围内进行分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance of dynamic line rating systems for wind integration
Different dynamic line rating systems have been developed in order to monitor lines and calculate the actual line rating. In this paper weather, conductor temperature and conductor tension based systems are analyzed. Measurements in two pilot lines were taken. One of them is the 66 kV evacuation line of a wind farm whereas, the other one is a 30 kV distribution line. In the analysis, actual rating values are calculated with the measurements of each system. Due to the fact that DLR results of the conductor temperature and conductor tension systems are inaccurate when differences between conductor temperature and ambient temperature are low, the analysis is made at different temperature ranges.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A single input dual buck-boost output reconfigurable converter for distributed generation Overhead transmission lines dynamic line rating estimation in WAMS environments Fast estimation of MPPs in mismatched PV arrays based on lossless model Frontiers of photovoltaic technology: A review Risk-based probabilistic approach to estimate power system security in the Sicilian context
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1