基于入侵杂草优化算法的约束约束机组调度问题求解

B. Saravanan, E. R. Vasudevan
{"title":"基于入侵杂草优化算法的约束约束机组调度问题求解","authors":"B. Saravanan, E. R. Vasudevan","doi":"10.1109/ICAEE.2014.6838532","DOIUrl":null,"url":null,"abstract":"With an increase in environmental considerations over the years, it has become extremely significant to reduce the emission levels in all areas of technology. Likewise, the problem of Unit Commitment (UC), which has always been thought of as a problem to reduce generation cost also involves an added objective of reducing emission levels. This paper presents a new methodology to solve this multi-objective problem. The problem of unit commitment keeping in mind the emission levels has been solved using the evolutionary algorithm of Invasive Weed Optimization (IWO). This proposed algorithm has been tested for two cases, eleven unit twenty four hour systems and eleven unit one sixty eight hour system. Both the results of unit commitment and emission levels have been obtained individually using IWO and the best solution has been achieved by compromising between emission levels and generation cost. This balance has been achieved using trade-off between the two separate solutions. The advantage of this new method gives much more accurate results for both emission and fuel cost which helps in achieving a better optimal solution using trade-offs.","PeriodicalId":151739,"journal":{"name":"2014 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Emission constrained unit commitment problem solution using invasive weed optimization Algorithm\",\"authors\":\"B. Saravanan, E. R. Vasudevan\",\"doi\":\"10.1109/ICAEE.2014.6838532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With an increase in environmental considerations over the years, it has become extremely significant to reduce the emission levels in all areas of technology. Likewise, the problem of Unit Commitment (UC), which has always been thought of as a problem to reduce generation cost also involves an added objective of reducing emission levels. This paper presents a new methodology to solve this multi-objective problem. The problem of unit commitment keeping in mind the emission levels has been solved using the evolutionary algorithm of Invasive Weed Optimization (IWO). This proposed algorithm has been tested for two cases, eleven unit twenty four hour systems and eleven unit one sixty eight hour system. Both the results of unit commitment and emission levels have been obtained individually using IWO and the best solution has been achieved by compromising between emission levels and generation cost. This balance has been achieved using trade-off between the two separate solutions. The advantage of this new method gives much more accurate results for both emission and fuel cost which helps in achieving a better optimal solution using trade-offs.\",\"PeriodicalId\":151739,\"journal\":{\"name\":\"2014 International Conference on Advances in Electrical Engineering (ICAEE)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Advances in Electrical Engineering (ICAEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAEE.2014.6838532\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2014.6838532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

随着多年来对环境考虑的增加,减少所有技术领域的排放水平变得极其重要。同样,一直被认为是降低发电成本问题的单位承诺问题也涉及到降低排放水平的附加目标。本文提出了一种解决多目标问题的新方法。采用入侵杂草优化(IWO)进化算法解决了考虑排放水平的机组承诺问题。该算法已在11个单位24小时制和11个单位68小时制两种情况下进行了测试。利用IWO分别获得了机组承诺和排放水平的结果,并在排放水平和发电成本之间进行了折衷,获得了最佳解决方案。这种平衡是通过在两个独立的解决方案之间进行权衡来实现的。这种新方法的优点是对排放和燃料成本都给出了更准确的结果,这有助于通过权衡获得更好的最佳解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Emission constrained unit commitment problem solution using invasive weed optimization Algorithm
With an increase in environmental considerations over the years, it has become extremely significant to reduce the emission levels in all areas of technology. Likewise, the problem of Unit Commitment (UC), which has always been thought of as a problem to reduce generation cost also involves an added objective of reducing emission levels. This paper presents a new methodology to solve this multi-objective problem. The problem of unit commitment keeping in mind the emission levels has been solved using the evolutionary algorithm of Invasive Weed Optimization (IWO). This proposed algorithm has been tested for two cases, eleven unit twenty four hour systems and eleven unit one sixty eight hour system. Both the results of unit commitment and emission levels have been obtained individually using IWO and the best solution has been achieved by compromising between emission levels and generation cost. This balance has been achieved using trade-off between the two separate solutions. The advantage of this new method gives much more accurate results for both emission and fuel cost which helps in achieving a better optimal solution using trade-offs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Linear Switched Reluctance Motor having gashed pole Economic load dispatch of thermal power plants using evolution technique including transmission losses Analysis and design of Peak Current controlled IBFC for high power factor and tight voltage regulation Automatic traffic control system for single lane tunnels Assessment of satellite image segmentation in RGB and HSV color space using image quality measures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1