热解吸管与不锈钢罐用于石油化工工厂挥发性有机物测定的比较。

Cheng-Ping Chang, T. Lin, Yu-Wen Lin, Yijin Hua, Wei-Ming Chu, Tzu-Yu Lin, Yi-Wen Lin, Jyun-De Wu
{"title":"热解吸管与不锈钢罐用于石油化工工厂挥发性有机物测定的比较。","authors":"Cheng-Ping Chang, T. Lin, Yu-Wen Lin, Yijin Hua, Wei-Ming Chu, Tzu-Yu Lin, Yi-Wen Lin, Jyun-De Wu","doi":"10.1093/annhyg/mev078","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nThe purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories.\n\n\nMETHODS\nTwelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant.\n\n\nRESULTS\nThe correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs.\n\n\nCONCLUSIONS\nThe comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated.","PeriodicalId":342592,"journal":{"name":"The Annals of occupational hygiene","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Comparison between Thermal Desorption Tubes and Stainless Steel Canisters Used for Measuring Volatile Organic Compounds in Petrochemical Factories.\",\"authors\":\"Cheng-Ping Chang, T. Lin, Yu-Wen Lin, Yijin Hua, Wei-Ming Chu, Tzu-Yu Lin, Yi-Wen Lin, Jyun-De Wu\",\"doi\":\"10.1093/annhyg/mev078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE\\nThe purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories.\\n\\n\\nMETHODS\\nTwelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant.\\n\\n\\nRESULTS\\nThe correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs.\\n\\n\\nCONCLUSIONS\\nThe comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated.\",\"PeriodicalId\":342592,\"journal\":{\"name\":\"The Annals of occupational hygiene\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Annals of occupational hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/annhyg/mev078\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Annals of occupational hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/annhyg/mev078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

目的比较热解吸管和不锈钢罐测量石油化工企业挥发性有机化合物(VOCs)的性能。方法选取麦寮工业园区12家石化工厂进行VOCs检测。采用热解吸管和6- 1特制不锈钢罐同时对环境空气样品进行主动采样。环境空气样本的采样时间设定在接近工人满班的6小时。采用热吸附管和不锈钢罐对石化工业总厂12家工厂的94份空气样本进行了成对采集。为了最大限度地增加比较数据点的数量,所有工厂在不同采样时间的所有测量结果被集中在一起,对每个选定的VOC进行线性回归分析。Pearson积矩相关系数用于检验这两种抽样方法的两两测量之间的相关性。还进行配对t检验,以检验两种方法测量的每种选定VOC浓度的差异是否具有统计学意义。结果丙酮、正己烷、苯、甲苯、1,2-二氯乙烷、1,3-丁二烯、苯乙烯等7种化合物的相关系数均为0.80,表明两种采样方法测量的VOCs具有较高的一致性。正己烷、苯、间/对二甲苯、邻二甲苯、1,2-二氯乙烷、1,3-丁二烯的配对t检验差异有统计学意义(p值< 0.05)。这说明两种抽样方法存在不同程度的系统误差。从六种化学物质的检测结果来看,这些系统误差可能是由于两种采样方法对这些挥发性有机化合物的检出限不同造成的。结论通过对两种取样方法测得的10种选定挥发性有机化合物的浓度进行比较,表明热脱附管对丙酮、苯和1,3-丁二烯的测定具有较高的准确度和精密度。由于吸附剂材料、多吸附剂设计和热解吸仪器的新发展,使用热解吸管测量挥发性有机化合物的准确性和精密度可以得到提高。热解吸管在测量职业和环境有害物质方面的更多应用可以预期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison between Thermal Desorption Tubes and Stainless Steel Canisters Used for Measuring Volatile Organic Compounds in Petrochemical Factories.
OBJECTIVE The purpose of this study was to compare thermal desorption tubes and stainless steel canisters for measuring volatile organic compounds (VOCs) emitted from petrochemical factories. METHODS Twelve petrochemical factories in the Mailiao Industrial Complex were recruited for conducting the measurements of VOCs. Thermal desorption tubes and 6-l specially prepared stainless steel canisters were used to simultaneously perform active sampling of environmental air samples. The sampling time of the environmental air samples was set up on 6 h close to a full work shift of the workers. A total of 94 pairwise air samples were collected by using the thermal adsorption tubes and stainless steel canisters in these 12 factories in the petrochemical industrial complex. To maximize the number of comparative data points, all the measurements from all the factories in different sampling times were lumped together to perform a linear regression analysis for each selected VOC. Pearson product-moment correlation coefficient was used to examine the correlation between the pairwise measurements of these two sampling methods. A paired t-test was also performed to examine whether the difference in the concentrations of each selected VOC measured by the two methods was statistically significant. RESULTS The correlation coefficients of seven compounds, including acetone, n-hexane, benzene, toluene, 1,2-dichloroethane, 1,3-butadiene, and styrene were >0.80 indicating the two sampling methods for these VOCs' measurements had high consistency. The paired t-tests for the measurements of n-hexane, benzene, m/p-xylene, o-xylene, 1,2-dichloroethane, and 1,3-butadiene showed statistically significant difference (P-value < 0.05). This indicated that the two sampling methods had various degrees of systematic errors. Looking at the results of six chemicals and these systematic errors probably resulted from the differences of the detection limits in the two sampling methods for these VOCs. CONCLUSIONS The comparison between the concentrations of each of the 10 selected VOCs measured by the two sampling methods indicted that the thermal desorption tubes provided high accuracy and precision measurements for acetone, benzene, and 1,3-butadiene. The accuracy and precision of using the thermal desorption tubes for measuring the VOCs can be improved due to new developments in sorbent materials, multi-sorbent designs, and thermal desorption instrumentation. More applications of thermal desorption tubes for measuring occupational and environmental hazardous agents can be anticipated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Response to Article by Prof. Hans Kromhout, Hygiene Without Numbers. The Validity and Applicability of Using a Generic Exposure Assessment Model for Occupational Exposure to Nano-Objects and Their Aggregates and Agglomerates. Occupational Exposure to Polycyclic Aromatic Hydrocarbons in Polish Coke Plant Workers. A New Miniature Respirable Sampler for In-mask Sampling: Part 2-Tests Performed Inside the Mask. When Are Risk Analyses on Job Titles Informative?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1