快速眼动睡眠的呼吸频率分类

G. Chung, B. H. Choi, K. Kim, Y. Lim, J. Choi, D. Jeong, K. Park
{"title":"快速眼动睡眠的呼吸频率分类","authors":"G. Chung, B. H. Choi, K. Kim, Y. Lim, J. Choi, D. Jeong, K. Park","doi":"10.1109/ITAB.2007.4407379","DOIUrl":null,"url":null,"abstract":"Polysomnagraphy, the method evaluating the sleep quality, is the reliable and standard method. However, to perform it, subject has to attach many sensors to their body. It seems intrusive, tangled and interrupting the subjects sleep. For the sake of monitoring the daily sleep pattern, simple method measuring the biosignal nonintrusively is needed. At that point, respiration is a beneficial signal, because it can be easily acquired by check the change of the thorax or abdomen. Respiration is one of the representatives of the reflection of the autonomic nervous system. According to the transition of the sleep stages, autonomic nervous system also changes and it can be shown by respiration. In this study, REM and non-REM sleep is classified by only using respiration for the 3 subjects. To enhance the performance, activity signal acquired by load-cell installed bed is added to divide the wake and REM sleep. At the results, hypnograms with polysomnagraphic data is compared with them. It can be seen that high correlation between the REM sleep and increasing pattern of the respiration rates.","PeriodicalId":129874,"journal":{"name":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","volume":"153 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":"{\"title\":\"REM Sleep Classification with Respiration Rates\",\"authors\":\"G. Chung, B. H. Choi, K. Kim, Y. Lim, J. Choi, D. Jeong, K. Park\",\"doi\":\"10.1109/ITAB.2007.4407379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Polysomnagraphy, the method evaluating the sleep quality, is the reliable and standard method. However, to perform it, subject has to attach many sensors to their body. It seems intrusive, tangled and interrupting the subjects sleep. For the sake of monitoring the daily sleep pattern, simple method measuring the biosignal nonintrusively is needed. At that point, respiration is a beneficial signal, because it can be easily acquired by check the change of the thorax or abdomen. Respiration is one of the representatives of the reflection of the autonomic nervous system. According to the transition of the sleep stages, autonomic nervous system also changes and it can be shown by respiration. In this study, REM and non-REM sleep is classified by only using respiration for the 3 subjects. To enhance the performance, activity signal acquired by load-cell installed bed is added to divide the wake and REM sleep. At the results, hypnograms with polysomnagraphic data is compared with them. It can be seen that high correlation between the REM sleep and increasing pattern of the respiration rates.\",\"PeriodicalId\":129874,\"journal\":{\"name\":\"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine\",\"volume\":\"153 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITAB.2007.4407379\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 6th International Special Topic Conference on Information Technology Applications in Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITAB.2007.4407379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

多导睡眠描记法是一种可靠、规范的睡眠质量评价方法。然而,要完成它,受试者必须在他们的身体上安装许多传感器。这似乎是侵入性的,混乱的,打断了受试者的睡眠。为了监测日常睡眠模式,需要一种简便、无创的生物信号测量方法。此时,呼吸是一个有益的信号,因为它可以很容易地通过检查胸部或腹部的变化来获得。呼吸是自主神经系统反映的代表之一。根据睡眠阶段的过渡,自主神经系统也会发生变化,这可以通过呼吸来表现。在本研究中,快速眼动睡眠和非快速眼动睡眠仅通过对3个受试者的呼吸进行分类。为了提高实验性能,在实验床上加入称重传感器采集到的活动信号,以区分清醒和快速眼动睡眠。在结果的基础上,将多导睡眠图与多导睡眠图进行比较。可以看出,快速眼动睡眠与呼吸频率增加模式之间存在高度相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
REM Sleep Classification with Respiration Rates
Polysomnagraphy, the method evaluating the sleep quality, is the reliable and standard method. However, to perform it, subject has to attach many sensors to their body. It seems intrusive, tangled and interrupting the subjects sleep. For the sake of monitoring the daily sleep pattern, simple method measuring the biosignal nonintrusively is needed. At that point, respiration is a beneficial signal, because it can be easily acquired by check the change of the thorax or abdomen. Respiration is one of the representatives of the reflection of the autonomic nervous system. According to the transition of the sleep stages, autonomic nervous system also changes and it can be shown by respiration. In this study, REM and non-REM sleep is classified by only using respiration for the 3 subjects. To enhance the performance, activity signal acquired by load-cell installed bed is added to divide the wake and REM sleep. At the results, hypnograms with polysomnagraphic data is compared with them. It can be seen that high correlation between the REM sleep and increasing pattern of the respiration rates.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wearable transducer to monitor respiration in a wireless way The relationship between HRV parameters and stressful driving situation in the real road Enforcing Privacy through Security in Remote Patient Monitoring Ecosystems Innovative Biomedical Information Technologies for Low-cost Healthcare Reflections on Information Technology in Biomedicine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1