数字微流控生物芯片生物化学分析中可感知布局的溶液制备

Sudip Roy, B. B. Bhattacharya, P. Chakrabarti, K. Chakrabarty
{"title":"数字微流控生物芯片生物化学分析中可感知布局的溶液制备","authors":"Sudip Roy, B. B. Bhattacharya, P. Chakrabarti, K. Chakrabarty","doi":"10.1109/VLSID.2011.55","DOIUrl":null,"url":null,"abstract":"A biochemical analysis is based on several laboratory protocols that require repeated mixing of samples with reagents. Sample preparation and analyte identification steps in such bioassays often involve mixing for solution preparation, i.e., various fluids are to be mixed in a certain volumetric ratio in their resulting mixture. We present an efficient approach for automated mixing of three or more fluids on a droplet based digital micro fluidic biochip and design a layout for implementing this algorithm. The proposed method reduces the droplet transportation time from boundary reservoirs to on chip mixers as well as cross-contamination among overlapping droplet routing paths. Simulation of several example solutions reveals encouraging results.","PeriodicalId":371062,"journal":{"name":"2011 24th Internatioal Conference on VLSI Design","volume":"130 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"Layout-Aware Solution Preparation for Biochemical Analysis on a Digital Microfluidic Biochip\",\"authors\":\"Sudip Roy, B. B. Bhattacharya, P. Chakrabarti, K. Chakrabarty\",\"doi\":\"10.1109/VLSID.2011.55\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A biochemical analysis is based on several laboratory protocols that require repeated mixing of samples with reagents. Sample preparation and analyte identification steps in such bioassays often involve mixing for solution preparation, i.e., various fluids are to be mixed in a certain volumetric ratio in their resulting mixture. We present an efficient approach for automated mixing of three or more fluids on a droplet based digital micro fluidic biochip and design a layout for implementing this algorithm. The proposed method reduces the droplet transportation time from boundary reservoirs to on chip mixers as well as cross-contamination among overlapping droplet routing paths. Simulation of several example solutions reveals encouraging results.\",\"PeriodicalId\":371062,\"journal\":{\"name\":\"2011 24th Internatioal Conference on VLSI Design\",\"volume\":\"130 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 24th Internatioal Conference on VLSI Design\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VLSID.2011.55\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 24th Internatioal Conference on VLSI Design","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSID.2011.55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40

摘要

生化分析是建立在若干实验室规程的基础上的,这些规程需要将样品与试剂反复混合。在这种生物测定中,样品制备和分析物鉴定步骤通常涉及溶液制备的混合,即各种流体在其所得混合物中以一定的体积比混合。我们提出了一种在基于液滴的数字微流体生物芯片上自动混合三种或三种以上流体的有效方法,并设计了实现该算法的布局。该方法减少了液滴从边界储层到片上混合器的运输时间,减少了重叠液滴路径之间的交叉污染。对几个示例解进行了仿真,得到了令人鼓舞的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Layout-Aware Solution Preparation for Biochemical Analysis on a Digital Microfluidic Biochip
A biochemical analysis is based on several laboratory protocols that require repeated mixing of samples with reagents. Sample preparation and analyte identification steps in such bioassays often involve mixing for solution preparation, i.e., various fluids are to be mixed in a certain volumetric ratio in their resulting mixture. We present an efficient approach for automated mixing of three or more fluids on a droplet based digital micro fluidic biochip and design a layout for implementing this algorithm. The proposed method reduces the droplet transportation time from boundary reservoirs to on chip mixers as well as cross-contamination among overlapping droplet routing paths. Simulation of several example solutions reveals encouraging results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Intra-Flit Skew Reduction for Asynchronous Bypass Channel in NoCs Multiple Fault Diagnosis Based on Multiple Fault Simulation Using Particle Swarm Optimization A GPU Algorithm for IC Floorplanning: Specification, Analysis and Optimization Low Offset, Low Noise, Variable Gain Interfacing Circuit with a Novel Scheme for Sensor Sensitivity and Offset Compensation for MEMS Based, Wheatstone Bridge Type, Resistive Smart Sensor Feedback Based Supply Voltage Control for Temperature Variation Tolerant PUFs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1