{"title":"小功率无故障检测间歇故障检测与隔离试验台的实验结果","authors":"M. Samie, Akbar Sheikh-Akbari, K. K. Singh, E. Ofoegbu","doi":"10.1109/MECO58584.2023.10155104","DOIUrl":null,"url":null,"abstract":"Applications in harsh environments greatly suffer from intermittency faults in their interconnections/wirings. Due to the erratic behavior of intermittency that causes signal irregularities, it is tough to distinguish irregularities from an actual transmitted signal, particularly in the earlier stages where signal abnormalities mainly resemble noise. This paper explores step changes in the resistance of a wire caused by broken strands as a failure parameter. Thus, a test rig was designed to emulate the ageing mechanism of the wire. with results of the study highlighting that resistance step changes could effectively be used to locate intermittency faults in low power cable applications.","PeriodicalId":187825,"journal":{"name":"2023 12th Mediterranean Conference on Embedded Computing (MECO)","volume":"522 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Results of an Intermittency Fault Detection and Isolation Test Rig for Low Power No-Fault-Found Applications\",\"authors\":\"M. Samie, Akbar Sheikh-Akbari, K. K. Singh, E. Ofoegbu\",\"doi\":\"10.1109/MECO58584.2023.10155104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Applications in harsh environments greatly suffer from intermittency faults in their interconnections/wirings. Due to the erratic behavior of intermittency that causes signal irregularities, it is tough to distinguish irregularities from an actual transmitted signal, particularly in the earlier stages where signal abnormalities mainly resemble noise. This paper explores step changes in the resistance of a wire caused by broken strands as a failure parameter. Thus, a test rig was designed to emulate the ageing mechanism of the wire. with results of the study highlighting that resistance step changes could effectively be used to locate intermittency faults in low power cable applications.\",\"PeriodicalId\":187825,\"journal\":{\"name\":\"2023 12th Mediterranean Conference on Embedded Computing (MECO)\",\"volume\":\"522 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Mediterranean Conference on Embedded Computing (MECO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MECO58584.2023.10155104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Mediterranean Conference on Embedded Computing (MECO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MECO58584.2023.10155104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在恶劣环境中的应用在其互连/布线中受到间歇性故障的极大影响。由于间歇性的不稳定行为会导致信号异常,因此很难将异常与实际传输的信号区分开来,特别是在信号异常主要类似于噪声的早期阶段。本文探讨了导线因断股引起的电阻阶跃变化作为失效参数。因此,设计了一个试验装置来模拟金属丝的老化机制。研究结果表明,电阻阶跃变化可以有效地用于小功率电缆间歇故障的定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental Results of an Intermittency Fault Detection and Isolation Test Rig for Low Power No-Fault-Found Applications
Applications in harsh environments greatly suffer from intermittency faults in their interconnections/wirings. Due to the erratic behavior of intermittency that causes signal irregularities, it is tough to distinguish irregularities from an actual transmitted signal, particularly in the earlier stages where signal abnormalities mainly resemble noise. This paper explores step changes in the resistance of a wire caused by broken strands as a failure parameter. Thus, a test rig was designed to emulate the ageing mechanism of the wire. with results of the study highlighting that resistance step changes could effectively be used to locate intermittency faults in low power cable applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Blockchain Platforms for Generation and Verification of Diplomas Minimizing the Total Completion Time of Jobs for a Permutation Flow-Shop System Double Buffered Angular Speed Measurement Method for Self-Calibration of Magnetoresistive Sensors Quantum Resilient Public Key Cryptography in Internet of Things Crop yield forecasting with climate data using PCA and Machine Learning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1