/sup 3/He用于TEXTOR的高功率中性束与/sup 4/He、氘和氢的55 KeV粒子束和真空系统数据的比较

R. Uhlemann, H. Reimer, M. Lochter
{"title":"/sup 3/He用于TEXTOR的高功率中性束与/sup 4/He、氘和氢的55 KeV粒子束和真空系统数据的比较","authors":"R. Uhlemann, H. Reimer, M. Lochter","doi":"10.1109/FUSION.1993.518377","DOIUrl":null,"url":null,"abstract":"Neutral particle beams of the /sup 3/He isotope in the megawatt range were successfully produced by the neutral beam injectors of TEXTOR. Measurements of beam and ion source characterizing data, i.e. perveance, divergence, neutralization efficiency, beamline transmission and gas flow rates for 50 kV, 49 A, 2.5 MW, 3 sec /sup 3/He beams are compared with relevant data of hydrogen, deuterium and /sup 4/He. The LHe cryo condensation pumps are capable of pumping the resulting /sup 3/He gas flow rates of 50 mbl/s without technical modification at 4.2 K, if covered prior to each beam pulse by an amount of argon frost with proper ratio of Ar/He. Beamline pressure, reionization losses and preliminary results of /sup 3/He-injection into TEXTOR are given.","PeriodicalId":365814,"journal":{"name":"15th IEEE/NPSS Symposium. Fusion Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"/sup 3/He high power neutral beams for TEXTOR comparison of 55 KeV particle beam and vacuum system data with /sup 4/He, deuterium and hydrogen\",\"authors\":\"R. Uhlemann, H. Reimer, M. Lochter\",\"doi\":\"10.1109/FUSION.1993.518377\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neutral particle beams of the /sup 3/He isotope in the megawatt range were successfully produced by the neutral beam injectors of TEXTOR. Measurements of beam and ion source characterizing data, i.e. perveance, divergence, neutralization efficiency, beamline transmission and gas flow rates for 50 kV, 49 A, 2.5 MW, 3 sec /sup 3/He beams are compared with relevant data of hydrogen, deuterium and /sup 4/He. The LHe cryo condensation pumps are capable of pumping the resulting /sup 3/He gas flow rates of 50 mbl/s without technical modification at 4.2 K, if covered prior to each beam pulse by an amount of argon frost with proper ratio of Ar/He. Beamline pressure, reionization losses and preliminary results of /sup 3/He-injection into TEXTOR are given.\",\"PeriodicalId\":365814,\"journal\":{\"name\":\"15th IEEE/NPSS Symposium. Fusion Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"15th IEEE/NPSS Symposium. Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.1993.518377\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th IEEE/NPSS Symposium. Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.1993.518377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

TEXTOR的中性束注入器成功地产生了兆瓦级/sup 3/He同位素的中性粒子束。将50 kV、49 A、2.5 MW、3 sec /sup 3/He束流的性能、发散度、中和效率、束流传输率和气体流速等束流和离子源表征数据与氢、氘和/sup 4/He束流的相关数据进行了比较。如果在每次光束脉冲之前覆盖一定量的氩/氦比合适的氩霜,LHe低温冷凝泵能够在4.2 K下泵出50mbl /s的/sup /He气体流速,而无需进行技术改造。给出了/sup 3/ he注入TEXTOR的束线压力、再电离损失和初步结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
/sup 3/He high power neutral beams for TEXTOR comparison of 55 KeV particle beam and vacuum system data with /sup 4/He, deuterium and hydrogen
Neutral particle beams of the /sup 3/He isotope in the megawatt range were successfully produced by the neutral beam injectors of TEXTOR. Measurements of beam and ion source characterizing data, i.e. perveance, divergence, neutralization efficiency, beamline transmission and gas flow rates for 50 kV, 49 A, 2.5 MW, 3 sec /sup 3/He beams are compared with relevant data of hydrogen, deuterium and /sup 4/He. The LHe cryo condensation pumps are capable of pumping the resulting /sup 3/He gas flow rates of 50 mbl/s without technical modification at 4.2 K, if covered prior to each beam pulse by an amount of argon frost with proper ratio of Ar/He. Beamline pressure, reionization losses and preliminary results of /sup 3/He-injection into TEXTOR are given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of sidestream recycle to the separation of hydrogen isotopes by cryogenic distillation Repair of poloidal field magnets on Alcator C-Mod Beam species mix as a function of DIII-D neutral beam ion source operation parameters Design of the TPX limiter and armor components Design, control and operation of the vacuum and gas systems for Alcator C-Mod
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1