增强占空比电流扫描仪的理论研究

V. Duma, A. Podoleanu
{"title":"增强占空比电流扫描仪的理论研究","authors":"V. Duma, A. Podoleanu","doi":"10.1117/12.810340","DOIUrl":null,"url":null,"abstract":"The paper explores the possibilities of achieving a galvanometric scanner with an enhanced, as close as possible to 100%, duty cycle (η) even for high scan, i.e. high oscillation, frequencies. Nowadays solutions provide high η, but up to certain frequencies. The study of this limit frequency, of its relationship with the duty cycle, and the ascertainment of the scanning and command functions that may produce better results, is the final scope of this work. The scanning device is considered in a setup characteristic to the dimensional, usually on-line, industrial measurements. A detailed theoretical study is performed, starting with the equation of the mobile element of the galvoscanner. The expressions of the active torque and of the necessary command function that has to be used are obtained, with regard to the desired scanning function. This is considered linear and symmetrical on its active portions and with non-linear returning portions that have to be performed as fast as possible. Two such functions for the returning portions are considered and studied: parabolic and sinusoidal. The best scanning function, with regard to achieving the objectives of the device (high duty cycle for high frequencies), is obtained and the way the necessary command function has to be deduced is discussed.","PeriodicalId":184459,"journal":{"name":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Theoretical approach on a galvanometric scanner with an enhanced duty cycle\",\"authors\":\"V. Duma, A. Podoleanu\",\"doi\":\"10.1117/12.810340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper explores the possibilities of achieving a galvanometric scanner with an enhanced, as close as possible to 100%, duty cycle (η) even for high scan, i.e. high oscillation, frequencies. Nowadays solutions provide high η, but up to certain frequencies. The study of this limit frequency, of its relationship with the duty cycle, and the ascertainment of the scanning and command functions that may produce better results, is the final scope of this work. The scanning device is considered in a setup characteristic to the dimensional, usually on-line, industrial measurements. A detailed theoretical study is performed, starting with the equation of the mobile element of the galvoscanner. The expressions of the active torque and of the necessary command function that has to be used are obtained, with regard to the desired scanning function. This is considered linear and symmetrical on its active portions and with non-linear returning portions that have to be performed as fast as possible. Two such functions for the returning portions are considered and studied: parabolic and sinusoidal. The best scanning function, with regard to achieving the objectives of the device (high duty cycle for high frequencies), is obtained and the way the necessary command function has to be deduced is discussed.\",\"PeriodicalId\":184459,\"journal\":{\"name\":\"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.810340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canterbury Workshop and School in Optical Coherence Tomography and Adaptive Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.810340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

本文探讨了实现高扫描,即高振荡频率,具有增强的,尽可能接近100%的占空比(η)的振镜扫描仪的可能性。现在的解决方案提供高η,但高达某些频率。研究这个极限频率,研究它与占空比的关系,以及确定可能产生更好结果的扫描和命令功能,是这项工作的最终范围。扫描装置被认为是尺寸的设置特性,通常是在线的,工业测量。从电激扫描仪的移动元件方程出发,进行了详细的理论研究。得到了所期望的扫描函数的主动转矩和必须使用的必要命令函数的表达式。这在其活动部分被认为是线性和对称的,而非线性返回部分必须尽可能快地执行。考虑并研究了返回部分的两种函数:抛物线函数和正弦函数。获得了实现器件目标(高频高占空比)的最佳扫描函数,并讨论了推导必要的命令函数的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Theoretical approach on a galvanometric scanner with an enhanced duty cycle
The paper explores the possibilities of achieving a galvanometric scanner with an enhanced, as close as possible to 100%, duty cycle (η) even for high scan, i.e. high oscillation, frequencies. Nowadays solutions provide high η, but up to certain frequencies. The study of this limit frequency, of its relationship with the duty cycle, and the ascertainment of the scanning and command functions that may produce better results, is the final scope of this work. The scanning device is considered in a setup characteristic to the dimensional, usually on-line, industrial measurements. A detailed theoretical study is performed, starting with the equation of the mobile element of the galvoscanner. The expressions of the active torque and of the necessary command function that has to be used are obtained, with regard to the desired scanning function. This is considered linear and symmetrical on its active portions and with non-linear returning portions that have to be performed as fast as possible. Two such functions for the returning portions are considered and studied: parabolic and sinusoidal. The best scanning function, with regard to achieving the objectives of the device (high duty cycle for high frequencies), is obtained and the way the necessary command function has to be deduced is discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Increasing signal-to-noise ratio of swept-source optical coherence tomography by oversampling in k-space Dental impression technique using optoelectronic devices Noise study of all-normal dispersion supercontinuum sources for potential application in optical coherence tomography Stable supercontinuum source based on random lasing Coherence and diffraction limited resolution in microscopic OCT by a unified approach for the correction of dispersion and aberrations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1