利用水文与探地雷达耦合反演估算地下水位动态水文参数

J. Bradford, M. Thoma, W. Barrash
{"title":"利用水文与探地雷达耦合反演估算地下水位动态水文参数","authors":"J. Bradford, M. Thoma, W. Barrash","doi":"10.1109/ICGPR.2014.6970420","DOIUrl":null,"url":null,"abstract":"During water table drawdown the differential relationship between hydraulic conductivity and the distance above the water saturated zone (SZ) leads to delay in drainage and stretching of the transition zone. The ground-penetrating radar (GPR) reflection from the SZ depends both on the width and shape of the transition zone, and dynamic changes of the saturation curve alter the GPR reflection amplitude, frequency, and phase. We have implemented a method to invert directly for van Genuchten-Mualem parameters from time-lapse GPR data acquired during a pumping test. The forward model consists of simulating the dynamic water saturation response to drawdown, integrated with a model of GPR response based on the full analytic reflectivity solution. We use a gradient based, multi-parameter method to optimize for an effective GPR source function and three van Genuchten-Mualem parameters Ks, n, and α, where Ks is the saturated hydraulic conductivity and n and α are fit parameters that control the shape of the soil-moisture retention curve. For field data acquired at the Boise Hydrogeophysical Research Site, this approach provided a hydrologic parameter set that substantially improved the fit to in-situ soil moisture curves over an initial “best-guess” model.","PeriodicalId":212710,"journal":{"name":"Proceedings of the 15th International Conference on Ground Penetrating Radar","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Estimating hydrologic parameters from water table dynamics using coupled hydrologic and ground-penetrating radar inversion\",\"authors\":\"J. Bradford, M. Thoma, W. Barrash\",\"doi\":\"10.1109/ICGPR.2014.6970420\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"During water table drawdown the differential relationship between hydraulic conductivity and the distance above the water saturated zone (SZ) leads to delay in drainage and stretching of the transition zone. The ground-penetrating radar (GPR) reflection from the SZ depends both on the width and shape of the transition zone, and dynamic changes of the saturation curve alter the GPR reflection amplitude, frequency, and phase. We have implemented a method to invert directly for van Genuchten-Mualem parameters from time-lapse GPR data acquired during a pumping test. The forward model consists of simulating the dynamic water saturation response to drawdown, integrated with a model of GPR response based on the full analytic reflectivity solution. We use a gradient based, multi-parameter method to optimize for an effective GPR source function and three van Genuchten-Mualem parameters Ks, n, and α, where Ks is the saturated hydraulic conductivity and n and α are fit parameters that control the shape of the soil-moisture retention curve. For field data acquired at the Boise Hydrogeophysical Research Site, this approach provided a hydrologic parameter set that substantially improved the fit to in-situ soil moisture curves over an initial “best-guess” model.\",\"PeriodicalId\":212710,\"journal\":{\"name\":\"Proceedings of the 15th International Conference on Ground Penetrating Radar\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 15th International Conference on Ground Penetrating Radar\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICGPR.2014.6970420\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 15th International Conference on Ground Penetrating Radar","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICGPR.2014.6970420","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

在地下水位下降过程中,水力导率与饱和带以上距离的差异关系导致排水延迟和过渡带拉伸。探地雷达在深水区的反射取决于过渡带的宽度和形状,饱和曲线的动态变化改变了探地雷达的反射幅度、频率和相位。我们已经实现了一种方法,可以从泵送测试期间获得的延时GPR数据中直接反演van Genuchten-Mualem参数。正演模型包括模拟含水饱和度对降压的动态响应,并结合基于全解析反射率解的探地雷达响应模型。我们使用基于梯度的多参数方法来优化有效的GPR源函数和三个van Genuchten-Mualem参数Ks, n和α,其中Ks是饱和水力导率,n和α是控制土壤水分保持曲线形状的拟合参数。对于在Boise水文地球物理研究基地获得的现场数据,该方法提供了一个水文参数集,与最初的“最佳猜测”模型相比,该方法大大提高了对原位土壤湿度曲线的拟合程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Estimating hydrologic parameters from water table dynamics using coupled hydrologic and ground-penetrating radar inversion
During water table drawdown the differential relationship between hydraulic conductivity and the distance above the water saturated zone (SZ) leads to delay in drainage and stretching of the transition zone. The ground-penetrating radar (GPR) reflection from the SZ depends both on the width and shape of the transition zone, and dynamic changes of the saturation curve alter the GPR reflection amplitude, frequency, and phase. We have implemented a method to invert directly for van Genuchten-Mualem parameters from time-lapse GPR data acquired during a pumping test. The forward model consists of simulating the dynamic water saturation response to drawdown, integrated with a model of GPR response based on the full analytic reflectivity solution. We use a gradient based, multi-parameter method to optimize for an effective GPR source function and three van Genuchten-Mualem parameters Ks, n, and α, where Ks is the saturated hydraulic conductivity and n and α are fit parameters that control the shape of the soil-moisture retention curve. For field data acquired at the Boise Hydrogeophysical Research Site, this approach provided a hydrologic parameter set that substantially improved the fit to in-situ soil moisture curves over an initial “best-guess” model.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Creating virtual vertical radar profiles from surface reflection Ground Penetrating Radar data Modeling of GPR data in a stack of VTI-layers with an analytical code Three-dimensional non-contact subsurface radiotomography through a non-planar interface between media Intrinsic modeling of antenna array in near-field conditions Cross-correlation attribute analysis of GPR data for tunnel engineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1