{"title":"同步相量数据在电力摆幅故障检测中的应用","authors":"J. Rao, A. Pradhan","doi":"10.1109/ICEAS.2011.6147180","DOIUrl":null,"url":null,"abstract":"Distance relays are blocked during power swing. However, if a fault occurs during power swing, it should be detected and unblocking function should be invoked to clear the fault as soon as possible. Detection of fault during power swing is a challenging task. The technology of synchronized phasor measurements has come of age and simplified the differential protection scheme. Differential protection scheme using synchrophasor data are applied in this paper to supplement the available fault detection techniques to distance relay for fault during power swing.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Application of synchrophasor data for fault detection during power swing\",\"authors\":\"J. Rao, A. Pradhan\",\"doi\":\"10.1109/ICEAS.2011.6147180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distance relays are blocked during power swing. However, if a fault occurs during power swing, it should be detected and unblocking function should be invoked to clear the fault as soon as possible. Detection of fault during power swing is a challenging task. The technology of synchronized phasor measurements has come of age and simplified the differential protection scheme. Differential protection scheme using synchrophasor data are applied in this paper to supplement the available fault detection techniques to distance relay for fault during power swing.\",\"PeriodicalId\":273164,\"journal\":{\"name\":\"2011 International Conference on Energy, Automation and Signal\",\"volume\":\"108 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Energy, Automation and Signal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEAS.2011.6147180\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of synchrophasor data for fault detection during power swing
Distance relays are blocked during power swing. However, if a fault occurs during power swing, it should be detected and unblocking function should be invoked to clear the fault as soon as possible. Detection of fault during power swing is a challenging task. The technology of synchronized phasor measurements has come of age and simplified the differential protection scheme. Differential protection scheme using synchrophasor data are applied in this paper to supplement the available fault detection techniques to distance relay for fault during power swing.