{"title":"学校设施使用后评价的框架模型","authors":"M. Hassanain, A. Iftikhar","doi":"10.1108/SS-06-2015-0029","DOIUrl":null,"url":null,"abstract":"Purpose – The purpose of this paper is to present an IDEF0 framework model for the post-occupancy evaluation of school facilities, and the findings of a case study to demonstrate the applicability of the framework. Design/methodology/approach – The framework model consists of five sequential processes, namely: first, identify the performance requirements of school facilities; second, conduct a walk-through evaluation and a focussed group discussion; third, develop and administer a user satisfaction survey; fourth, analyze the collected data and report the findings; and fifth, develop a plan of remedial actions. Findings – The case study demonstrates the applicability of the framework through presenting the findings of an indicative evaluation of the major technical and functional elements of performance carried out on a school building in city of Khobar, Eastern Province of Saudi Arabia. The school users were satisfied with the qualities of the thermal comfort, visual comfort, fire protection, functional ...","PeriodicalId":118605,"journal":{"name":"Structural Survey","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":"{\"title\":\"Framework model for post-occupancy evaluation of school facilities\",\"authors\":\"M. Hassanain, A. Iftikhar\",\"doi\":\"10.1108/SS-06-2015-0029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose – The purpose of this paper is to present an IDEF0 framework model for the post-occupancy evaluation of school facilities, and the findings of a case study to demonstrate the applicability of the framework. Design/methodology/approach – The framework model consists of five sequential processes, namely: first, identify the performance requirements of school facilities; second, conduct a walk-through evaluation and a focussed group discussion; third, develop and administer a user satisfaction survey; fourth, analyze the collected data and report the findings; and fifth, develop a plan of remedial actions. Findings – The case study demonstrates the applicability of the framework through presenting the findings of an indicative evaluation of the major technical and functional elements of performance carried out on a school building in city of Khobar, Eastern Province of Saudi Arabia. The school users were satisfied with the qualities of the thermal comfort, visual comfort, fire protection, functional ...\",\"PeriodicalId\":118605,\"journal\":{\"name\":\"Structural Survey\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"54\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Structural Survey\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/SS-06-2015-0029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Survey","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/SS-06-2015-0029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Framework model for post-occupancy evaluation of school facilities
Purpose – The purpose of this paper is to present an IDEF0 framework model for the post-occupancy evaluation of school facilities, and the findings of a case study to demonstrate the applicability of the framework. Design/methodology/approach – The framework model consists of five sequential processes, namely: first, identify the performance requirements of school facilities; second, conduct a walk-through evaluation and a focussed group discussion; third, develop and administer a user satisfaction survey; fourth, analyze the collected data and report the findings; and fifth, develop a plan of remedial actions. Findings – The case study demonstrates the applicability of the framework through presenting the findings of an indicative evaluation of the major technical and functional elements of performance carried out on a school building in city of Khobar, Eastern Province of Saudi Arabia. The school users were satisfied with the qualities of the thermal comfort, visual comfort, fire protection, functional ...