{"title":"用于医疗保健和运动应用的高分辨率微型MET传感器","authors":"D. Zaitsev, E. Egorov, A. Shabalina","doi":"10.1109/ICSENST.2018.8603579","DOIUrl":null,"url":null,"abstract":"A device has been developed for determining the motion parameters of the human body and lower limbs intended for use in orthopedic healthcare facilities, treatment and prevention of musculoskeletal system disorders, sports medicine. The layout of a miniature detector of movement parameters, consisting of six miniatures high precision molecular-electronic technology (MET) sensors (three linear motion sensors and three angular motion sensors) designed to be fixed on human lower limbs and body, was developed and constructed. Data processing algorithms have been developed to define, in addition to the provided instrumentally accurate data on linear and angular motion parameters at sensor fixation points, the major phases of motion corresponding to the periods of rest, start and end of the motion, as well as the actual movements of human limbs and body.","PeriodicalId":181015,"journal":{"name":"2018 12th International Conference on Sensing Technology (ICST)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"High resolution miniature MET sensors for healthcare and sport applications\",\"authors\":\"D. Zaitsev, E. Egorov, A. Shabalina\",\"doi\":\"10.1109/ICSENST.2018.8603579\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A device has been developed for determining the motion parameters of the human body and lower limbs intended for use in orthopedic healthcare facilities, treatment and prevention of musculoskeletal system disorders, sports medicine. The layout of a miniature detector of movement parameters, consisting of six miniatures high precision molecular-electronic technology (MET) sensors (three linear motion sensors and three angular motion sensors) designed to be fixed on human lower limbs and body, was developed and constructed. Data processing algorithms have been developed to define, in addition to the provided instrumentally accurate data on linear and angular motion parameters at sensor fixation points, the major phases of motion corresponding to the periods of rest, start and end of the motion, as well as the actual movements of human limbs and body.\",\"PeriodicalId\":181015,\"journal\":{\"name\":\"2018 12th International Conference on Sensing Technology (ICST)\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 12th International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2018.8603579\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 12th International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2018.8603579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

已经开发了一种用于确定人体和下肢运动参数的装置,用于骨科保健设施,肌肉骨骼系统疾病的治疗和预防,运动医学。设计并构建了由6个微型高精度分子电子技术(MET)传感器(3个线性运动传感器和3个角运动传感器)固定在人体下肢和身体上的微型运动参数检测器的布局。数据处理算法已经被开发出来,除了在传感器固定点提供的关于线性和角运动参数的仪器精确数据外,还定义了运动的主要阶段,对应于运动的休息、开始和结束时期,以及人体四肢和身体的实际运动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High resolution miniature MET sensors for healthcare and sport applications
A device has been developed for determining the motion parameters of the human body and lower limbs intended for use in orthopedic healthcare facilities, treatment and prevention of musculoskeletal system disorders, sports medicine. The layout of a miniature detector of movement parameters, consisting of six miniatures high precision molecular-electronic technology (MET) sensors (three linear motion sensors and three angular motion sensors) designed to be fixed on human lower limbs and body, was developed and constructed. Data processing algorithms have been developed to define, in addition to the provided instrumentally accurate data on linear and angular motion parameters at sensor fixation points, the major phases of motion corresponding to the periods of rest, start and end of the motion, as well as the actual movements of human limbs and body.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Contact Area Design of Ohmic RF MEMS Switch for Enhanced Power Handling Adaptive Energy Optimization Algorithm for Internet of Medical Things Automatic System for Li-Ion Battery Packs Gas Leakage Detection Flexible Al/PZT/Al composite for piezoelectric applications Detection and characterization of surfing events with smartphones’ embedded sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1