将运动控制界面和移动性集成到3D手术PACS中

B. J. Park, Taekjin Jang, J. Choi, Namkug Kim
{"title":"将运动控制界面和移动性集成到3D手术PACS中","authors":"B. J. Park, Taekjin Jang, J. Choi, Namkug Kim","doi":"10.1109/ICIEV.2015.7334069","DOIUrl":null,"url":null,"abstract":"We developed a contactless interface for effectively controlling 2D and 3D medical images in operating rooms, which was implemented in the in-house 3D PACS program with a sensor device, a foot pedal and a mobile workstation. Various pre-defined hand motions and gestures were used for rotating, zooming, panning images or mimicking the movement of a mouse to the monitor screen. The software was installed and tested in a mobile workstation, which was moved to the operating room to be able to control medical images while maintaining aseptic conditions. Performance testing of this interface was evaluated by radiologists and was successfully used in practice by surgeons.","PeriodicalId":367355,"journal":{"name":"2015 International Conference on Informatics, Electronics & Vision (ICIEV)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Integrating motion controlled interface and mobility into 3D PACS for surgery\",\"authors\":\"B. J. Park, Taekjin Jang, J. Choi, Namkug Kim\",\"doi\":\"10.1109/ICIEV.2015.7334069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a contactless interface for effectively controlling 2D and 3D medical images in operating rooms, which was implemented in the in-house 3D PACS program with a sensor device, a foot pedal and a mobile workstation. Various pre-defined hand motions and gestures were used for rotating, zooming, panning images or mimicking the movement of a mouse to the monitor screen. The software was installed and tested in a mobile workstation, which was moved to the operating room to be able to control medical images while maintaining aseptic conditions. Performance testing of this interface was evaluated by radiologists and was successfully used in practice by surgeons.\",\"PeriodicalId\":367355,\"journal\":{\"name\":\"2015 International Conference on Informatics, Electronics & Vision (ICIEV)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Informatics, Electronics & Vision (ICIEV)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEV.2015.7334069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Informatics, Electronics & Vision (ICIEV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEV.2015.7334069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

我们开发了一种非接触式界面,用于有效控制手术室的二维和三维医学图像,并在内部3D PACS程序中通过传感器设备、脚踏板和移动工作站实现。各种预先定义的手部动作和手势用于旋转、缩放、平移图像或模仿鼠标到显示器屏幕的移动。该软件在移动工作站中安装和测试,移动工作站被移至手术室,以便能够在保持无菌条件的同时控制医学图像。放射科医生评估了该接口的性能测试,并成功地在外科医生的实践中使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Integrating motion controlled interface and mobility into 3D PACS for surgery
We developed a contactless interface for effectively controlling 2D and 3D medical images in operating rooms, which was implemented in the in-house 3D PACS program with a sensor device, a foot pedal and a mobile workstation. Various pre-defined hand motions and gestures were used for rotating, zooming, panning images or mimicking the movement of a mouse to the monitor screen. The software was installed and tested in a mobile workstation, which was moved to the operating room to be able to control medical images while maintaining aseptic conditions. Performance testing of this interface was evaluated by radiologists and was successfully used in practice by surgeons.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Static output feedback control design for Takagi-Sugeno descriptor fuzzy systems FRIT based PI tuning for speed control of PMSM using FPGA for high frequency SiC MOSFET inverter A homogeneous region based methodology for text extraction from natural scene images People re-identification using 3D descriptor with skeleton information Development of battery-shaped device unified communication line and power line
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1