基于遗传算法的TCSC补偿输电线路故障分类新方法

P. Tripathi, G. Pillai, H. Gupta
{"title":"基于遗传算法的TCSC补偿输电线路故障分类新方法","authors":"P. Tripathi, G. Pillai, H. Gupta","doi":"10.1109/POWERCON.2012.6401382","DOIUrl":null,"url":null,"abstract":"Presence of TCSC (Thyristor-Controlled Series Compensator) compensated transmission lines is increasing in modern power systems due to their benefits like increased power flow capacity but these benefits come at the cost of difficulty in protection of the transmission line. This paper presents a new method using SVM (Support Vector Machine) for fault classification in such line. This method is compared with existing SVM based methods and higher classification accuracy has been achieved. The improved accuracy is achieved by changing the architecture and input of the classifier. Genetic Algorithm (GA) is used to search globally optimum value of SVM parameters. Effect of sampling frequency and data window length on proposed scheme is also analyzed.","PeriodicalId":176214,"journal":{"name":"2012 IEEE International Conference on Power System Technology (POWERCON)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"New method for fault classification in TCSC compensated transmission line using GA tuned SVM\",\"authors\":\"P. Tripathi, G. Pillai, H. Gupta\",\"doi\":\"10.1109/POWERCON.2012.6401382\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Presence of TCSC (Thyristor-Controlled Series Compensator) compensated transmission lines is increasing in modern power systems due to their benefits like increased power flow capacity but these benefits come at the cost of difficulty in protection of the transmission line. This paper presents a new method using SVM (Support Vector Machine) for fault classification in such line. This method is compared with existing SVM based methods and higher classification accuracy has been achieved. The improved accuracy is achieved by changing the architecture and input of the classifier. Genetic Algorithm (GA) is used to search globally optimum value of SVM parameters. Effect of sampling frequency and data window length on proposed scheme is also analyzed.\",\"PeriodicalId\":176214,\"journal\":{\"name\":\"2012 IEEE International Conference on Power System Technology (POWERCON)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Power System Technology (POWERCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2012.6401382\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Power System Technology (POWERCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2012.6401382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

TCSC(晶闸管控制串联补偿器)补偿输电线路在现代电力系统中的应用越来越多,因为它可以增加潮流容量,但这些好处是以输电线路保护困难为代价的。本文提出了一种基于支持向量机的故障分类方法。将该方法与现有的基于支持向量机的方法进行了比较,得到了更高的分类精度。通过改变分类器的结构和输入来提高准确率。采用遗传算法对支持向量机参数进行全局寻优。分析了采样频率和数据窗长度对方案的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New method for fault classification in TCSC compensated transmission line using GA tuned SVM
Presence of TCSC (Thyristor-Controlled Series Compensator) compensated transmission lines is increasing in modern power systems due to their benefits like increased power flow capacity but these benefits come at the cost of difficulty in protection of the transmission line. This paper presents a new method using SVM (Support Vector Machine) for fault classification in such line. This method is compared with existing SVM based methods and higher classification accuracy has been achieved. The improved accuracy is achieved by changing the architecture and input of the classifier. Genetic Algorithm (GA) is used to search globally optimum value of SVM parameters. Effect of sampling frequency and data window length on proposed scheme is also analyzed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A study on global solar radiation forecasting models using meteorological data and their application to wide area forecast Adaptive Frequency Control for Hybrid Wind-Diesel power system using system estimator Smart grid standards for home and building automation Demand response plan considering available spinning reserve for system frequency restoration Economic evaluation of grid-connected solar PV production cost in New Zealand
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1