{"title":"配电网功率限值的定义和计算。需求侧综合管理的基础","authors":"Tobias Heß, P. Schegner","doi":"10.1109/ISGTEurope.2018.8571848","DOIUrl":null,"url":null,"abstract":"In order to achieve the objectives of the energy transition, flexibility of demand and generation has to be utilized with the coupling of different energy sectors. To avoid congestion in the distribution network a pure market-based integration of flexible units is not permitted. Rather, a comprehensive demand side management (DSM) similar to the management in the transmission grid is necessary. In contrast to transmission grid the method has to be automated and has to provide a simple parameter which describes the grid capacity. This paper defines therefore the power limit value (PLV) of the distribution grid. The PLV is thereby determined on the basis of a forecast of all non-controllable loads and generation units in the network. The calculated values define limits within the planing period were energy trade can take place without restrictions. The paper presents a method for calculating the PLV. The usage of the method is illustrated in a low voltage distribution grid.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"109 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Definition and Calculation of Power Limit Values for Distribution Grids - Basics of Comprehensive Demand Side Managemen\",\"authors\":\"Tobias Heß, P. Schegner\",\"doi\":\"10.1109/ISGTEurope.2018.8571848\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to achieve the objectives of the energy transition, flexibility of demand and generation has to be utilized with the coupling of different energy sectors. To avoid congestion in the distribution network a pure market-based integration of flexible units is not permitted. Rather, a comprehensive demand side management (DSM) similar to the management in the transmission grid is necessary. In contrast to transmission grid the method has to be automated and has to provide a simple parameter which describes the grid capacity. This paper defines therefore the power limit value (PLV) of the distribution grid. The PLV is thereby determined on the basis of a forecast of all non-controllable loads and generation units in the network. The calculated values define limits within the planing period were energy trade can take place without restrictions. The paper presents a method for calculating the PLV. The usage of the method is illustrated in a low voltage distribution grid.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"109 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571848\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571848","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Definition and Calculation of Power Limit Values for Distribution Grids - Basics of Comprehensive Demand Side Managemen
In order to achieve the objectives of the energy transition, flexibility of demand and generation has to be utilized with the coupling of different energy sectors. To avoid congestion in the distribution network a pure market-based integration of flexible units is not permitted. Rather, a comprehensive demand side management (DSM) similar to the management in the transmission grid is necessary. In contrast to transmission grid the method has to be automated and has to provide a simple parameter which describes the grid capacity. This paper defines therefore the power limit value (PLV) of the distribution grid. The PLV is thereby determined on the basis of a forecast of all non-controllable loads and generation units in the network. The calculated values define limits within the planing period were energy trade can take place without restrictions. The paper presents a method for calculating the PLV. The usage of the method is illustrated in a low voltage distribution grid.