如果储层含有低电阻率环空带,则进行多探头低频感应测井和高频感应测井

K. V. Suhorukova, S. V. Ananyev, A. M. Petrov, O. Nechaev
{"title":"如果储层含有低电阻率环空带,则进行多探头低频感应测井和高频感应测井","authors":"K. V. Suhorukova, S. V. Ananyev, A. M. Petrov, O. Nechaev","doi":"10.18303/2619-1563-2022-1-17","DOIUrl":null,"url":null,"abstract":"A low resistivity annulus appearing near the well due to reservoir fluid displacement by mud filtrate is a reliable indicator of movable oil presence in the reservoir. In practical cases estimation of low resistivity annulus parameters is possible based on high-frequency induction logging data analysis. When interpreting practical data of other resistivity logging methods its influence on signals is usually not taken into account. The paper discusses the results of the 5IK and VIKIZ logs numerical simulation which substantiate the possibility of identifying low resistivity annulus according to multi-probe low-frequency induction logging in geoelectric conditions typical for the Cretaceous mixed-saturation reservoirs of the Imilorskoye oilfield.","PeriodicalId":190530,"journal":{"name":"Russian Journal of Geophysical Technologies","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Multi-probe low-frequency induction log and high-frequency induction log if the reservoir contains the low resistivity annulus zone\",\"authors\":\"K. V. Suhorukova, S. V. Ananyev, A. M. Petrov, O. Nechaev\",\"doi\":\"10.18303/2619-1563-2022-1-17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A low resistivity annulus appearing near the well due to reservoir fluid displacement by mud filtrate is a reliable indicator of movable oil presence in the reservoir. In practical cases estimation of low resistivity annulus parameters is possible based on high-frequency induction logging data analysis. When interpreting practical data of other resistivity logging methods its influence on signals is usually not taken into account. The paper discusses the results of the 5IK and VIKIZ logs numerical simulation which substantiate the possibility of identifying low resistivity annulus according to multi-probe low-frequency induction logging in geoelectric conditions typical for the Cretaceous mixed-saturation reservoirs of the Imilorskoye oilfield.\",\"PeriodicalId\":190530,\"journal\":{\"name\":\"Russian Journal of Geophysical Technologies\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Russian Journal of Geophysical Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18303/2619-1563-2022-1-17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Geophysical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18303/2619-1563-2022-1-17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于泥浆滤液对储层流体的驱替,在井附近出现的低电阻率环空是储层中存在可动油的可靠指标。在实际应用中,利用高频感应测井资料进行低电阻率环空参数估计是可行的。在解释其他电阻率测井方法的实际资料时,通常不考虑其对信号的影响。本文讨论了5IK和VIKIZ测井数值模拟的结果,证实了Imilorskoye油田白垩系混饱和储层典型地电条件下多探头低频感应测井识别低电阻率环空的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Multi-probe low-frequency induction log and high-frequency induction log if the reservoir contains the low resistivity annulus zone
A low resistivity annulus appearing near the well due to reservoir fluid displacement by mud filtrate is a reliable indicator of movable oil presence in the reservoir. In practical cases estimation of low resistivity annulus parameters is possible based on high-frequency induction logging data analysis. When interpreting practical data of other resistivity logging methods its influence on signals is usually not taken into account. The paper discusses the results of the 5IK and VIKIZ logs numerical simulation which substantiate the possibility of identifying low resistivity annulus according to multi-probe low-frequency induction logging in geoelectric conditions typical for the Cretaceous mixed-saturation reservoirs of the Imilorskoye oilfield.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Discrete element based numerical simulation of granular material fracturing Fan mechanism creating dynamic ruptures with high permeability at seismogenic depths of the Earth’s crust Research of the microstructure features of Bazhenov deposits and selection of the optimal model for creating a digital twin of the rock Multiscale geomechanical modeling taking into account the evolution of the microstructure of the geological media Transient electromagnetic cross-borehole exploration for monitoring the state of the cryolithozone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1