{"title":"球面内有约束熔化与无约束熔化的比较研究","authors":"R. Kothari, S. Revankar, S. Sahu, S. I. Kundalwal","doi":"10.1115/icone2020-16056","DOIUrl":null,"url":null,"abstract":"\n Present study is focused on the computational analysis of melting of PCM inside the spherical capsule. Both unconstrained and constrained melting is analyzed for the constant PCM volume and similar initial and boundary conditions. RT27 is chosen as the PCM for this study. Air is considered at the top of PCM inside the spherical capsule. Results are validated with the existing experimental and computational results and found to be in good agreement. Results obtained from present study are compared for the melting fraction, pattern and time. Composite diagrams are presented for the streamline and temperature contours.","PeriodicalId":414088,"journal":{"name":"Volume 3: Student Paper Competition; Thermal-Hydraulics; Verification and Validation","volume":"232 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Comparative Study of Constrained and Unconstrained Melting Inside a Sphere\",\"authors\":\"R. Kothari, S. Revankar, S. Sahu, S. I. Kundalwal\",\"doi\":\"10.1115/icone2020-16056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Present study is focused on the computational analysis of melting of PCM inside the spherical capsule. Both unconstrained and constrained melting is analyzed for the constant PCM volume and similar initial and boundary conditions. RT27 is chosen as the PCM for this study. Air is considered at the top of PCM inside the spherical capsule. Results are validated with the existing experimental and computational results and found to be in good agreement. Results obtained from present study are compared for the melting fraction, pattern and time. Composite diagrams are presented for the streamline and temperature contours.\",\"PeriodicalId\":414088,\"journal\":{\"name\":\"Volume 3: Student Paper Competition; Thermal-Hydraulics; Verification and Validation\",\"volume\":\"232 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Student Paper Competition; Thermal-Hydraulics; Verification and Validation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/icone2020-16056\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Student Paper Competition; Thermal-Hydraulics; Verification and Validation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/icone2020-16056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Comparative Study of Constrained and Unconstrained Melting Inside a Sphere
Present study is focused on the computational analysis of melting of PCM inside the spherical capsule. Both unconstrained and constrained melting is analyzed for the constant PCM volume and similar initial and boundary conditions. RT27 is chosen as the PCM for this study. Air is considered at the top of PCM inside the spherical capsule. Results are validated with the existing experimental and computational results and found to be in good agreement. Results obtained from present study are compared for the melting fraction, pattern and time. Composite diagrams are presented for the streamline and temperature contours.