M. Keshtkar
{"title":"跨临界二氧化碳压缩循环的数值分析:一个案例研究","authors":"M. Keshtkar","doi":"10.14419/JACST.V7I1.8827","DOIUrl":null,"url":null,"abstract":"This study deals with thermodynamic investigation of a refrigeration compression cycle with carbon dioxide refrigerant and two stage compression. In this paper, the effect of intercooler in the two-stage compression system at different pressures of gas cooler is investigated. In addition, the performance of one stage compression cycle and two-stage compression cycle are compared and eventually, the performance of system is investigated under the influence of the change of variables such as gas cooler pressure, isentropic efficiency of the compressors, the intercooling rate between the two stages of compression, the refrigerant gas cooler outlet temperature is examined. Due to evaporation temperature in the evaporator   10 C  and refrigeration capacity (kW) results show that the coefficient of performance in the two-stage compression with intercooler is increased compared to the single-stage compression cycle.","PeriodicalId":445404,"journal":{"name":"Journal of Advanced Computer Science and Technology","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Numerical analysis of transcritical carbon dioxide compression cycle: a case study\",\"authors\":\"M. Keshtkar\",\"doi\":\"10.14419/JACST.V7I1.8827\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study deals with thermodynamic investigation of a refrigeration compression cycle with carbon dioxide refrigerant and two stage compression. In this paper, the effect of intercooler in the two-stage compression system at different pressures of gas cooler is investigated. In addition, the performance of one stage compression cycle and two-stage compression cycle are compared and eventually, the performance of system is investigated under the influence of the change of variables such as gas cooler pressure, isentropic efficiency of the compressors, the intercooling rate between the two stages of compression, the refrigerant gas cooler outlet temperature is examined. Due to evaporation temperature in the evaporator   10 C  and refrigeration capacity (kW) results show that the coefficient of performance in the two-stage compression with intercooler is increased compared to the single-stage compression cycle.\",\"PeriodicalId\":445404,\"journal\":{\"name\":\"Journal of Advanced Computer Science and Technology\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Computer Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14419/JACST.V7I1.8827\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Computer Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14419/JACST.V7I1.8827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

本文对含二氧化碳制冷剂和两级压缩的制冷压缩循环进行了热力学研究。本文研究了在不同气体冷却器压力下,中间冷却器在两级压缩系统中的作用。此外,还对一级压缩循环和二级压缩循环的性能进行了比较,最后考察了气冷器压力、压缩机等熵效率、两级压缩间的中间冷却速率、制冷剂气冷器出口温度等变量变化对系统性能的影响。由于蒸发器的蒸发温度10℃,制冷量(kW),结果表明,与单级压缩循环相比,带中间冷却器的两级压缩循环的性能系数有所提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical analysis of transcritical carbon dioxide compression cycle: a case study
This study deals with thermodynamic investigation of a refrigeration compression cycle with carbon dioxide refrigerant and two stage compression. In this paper, the effect of intercooler in the two-stage compression system at different pressures of gas cooler is investigated. In addition, the performance of one stage compression cycle and two-stage compression cycle are compared and eventually, the performance of system is investigated under the influence of the change of variables such as gas cooler pressure, isentropic efficiency of the compressors, the intercooling rate between the two stages of compression, the refrigerant gas cooler outlet temperature is examined. Due to evaporation temperature in the evaporator   10 C  and refrigeration capacity (kW) results show that the coefficient of performance in the two-stage compression with intercooler is increased compared to the single-stage compression cycle.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluating the performance of machine learning algorithms for network intrusion detection systems in the internet of things infrastructure Geometric Approach to Optimal Path Problem with Uncertain Arc Lengths Statistical adjustment of the parameters of multi-objective optimization problems with design expert method Circular Gabor wavelet algorithm for fingerprint liveness detection Numerical analysis of transcritical carbon dioxide compression cycle: a case study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1