R. Laouamer, M. Brunello, J. Ferrieux, O. Normand, N. Buchheit
{"title":"一种用于电磁耦合非接触充电的多谐振变换器","authors":"R. Laouamer, M. Brunello, J. Ferrieux, O. Normand, N. Buchheit","doi":"10.1109/IECON.1997.671998","DOIUrl":null,"url":null,"abstract":"A parallel resonant power converter (PRC-LLCC) is analyzed for automatic inductive charging applications. The tank circuit of this power converter consists of a leakage inductance, a magnetizing inductance and two power capacitors with an inductive output filter. This converter allows the transfer of power without oversizing the inverter and a soft-switching mode of the transistors. The soft-switching mode and the sensitivity to the load variation, the coupling factor and the air gap (6-8 mm) are studied using the first harmonic method. The choice of the working range and the validity limit of the analysis method are presented. Theoretical results are validated experimentally with a 3 kW prototype.","PeriodicalId":404447,"journal":{"name":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","volume":"316 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"91","resultStr":"{\"title\":\"A multi-resonant converter for non-contact charging with electromagnetic coupling\",\"authors\":\"R. Laouamer, M. Brunello, J. Ferrieux, O. Normand, N. Buchheit\",\"doi\":\"10.1109/IECON.1997.671998\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A parallel resonant power converter (PRC-LLCC) is analyzed for automatic inductive charging applications. The tank circuit of this power converter consists of a leakage inductance, a magnetizing inductance and two power capacitors with an inductive output filter. This converter allows the transfer of power without oversizing the inverter and a soft-switching mode of the transistors. The soft-switching mode and the sensitivity to the load variation, the coupling factor and the air gap (6-8 mm) are studied using the first harmonic method. The choice of the working range and the validity limit of the analysis method are presented. Theoretical results are validated experimentally with a 3 kW prototype.\",\"PeriodicalId\":404447,\"journal\":{\"name\":\"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)\",\"volume\":\"316 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"91\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.1997.671998\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IECON'97 23rd International Conference on Industrial Electronics, Control, and Instrumentation (Cat. No.97CH36066)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.1997.671998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A multi-resonant converter for non-contact charging with electromagnetic coupling
A parallel resonant power converter (PRC-LLCC) is analyzed for automatic inductive charging applications. The tank circuit of this power converter consists of a leakage inductance, a magnetizing inductance and two power capacitors with an inductive output filter. This converter allows the transfer of power without oversizing the inverter and a soft-switching mode of the transistors. The soft-switching mode and the sensitivity to the load variation, the coupling factor and the air gap (6-8 mm) are studied using the first harmonic method. The choice of the working range and the validity limit of the analysis method are presented. Theoretical results are validated experimentally with a 3 kW prototype.