踝腱反射评估训练医学教育模拟器的对照设计与初步评价

Yinan Pei, Christopher M. Zallek, E. Hsiao-Wecksler
{"title":"踝腱反射评估训练医学教育模拟器的对照设计与初步评价","authors":"Yinan Pei, Christopher M. Zallek, E. Hsiao-Wecksler","doi":"10.1115/dmd2022-1072","DOIUrl":null,"url":null,"abstract":"\n Ankle (or Achilles) tendon reflex is commonly assessed in a neurological examination. For a clinician trainee to master the correct assessment technique of Achilles tendon reflex and to be able to distinguish among various reflex activity levels indicating health or abnormality, repetitive training and practice are necessary. We propose to develop a robotic medical education training simulator that would generate a realistic reflex behavior depending on the simulated reflex activity level selected when given a tendon tap assessment. This development was based on an existing ankle-foot simulator [5]. A modified sensing system is still under development. In this paper, a reflex model was developed to estimate the ankle reflexive torque based on the input tap force. This reflex model prediction was validated in simulation and then implemented into our robotic simulator prototype. Preliminary benchtop results demonstrated that our simulator was able to accurately deliver the reflexive torque pattern required to simulate the clinical reflex movement to the trainee.","PeriodicalId":236105,"journal":{"name":"2022 Design of Medical Devices Conference","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Control Design and Preliminary Evaluation of a Medical Education Simulator for Ankle Tendon Reflex Assessment Training\",\"authors\":\"Yinan Pei, Christopher M. Zallek, E. Hsiao-Wecksler\",\"doi\":\"10.1115/dmd2022-1072\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Ankle (or Achilles) tendon reflex is commonly assessed in a neurological examination. For a clinician trainee to master the correct assessment technique of Achilles tendon reflex and to be able to distinguish among various reflex activity levels indicating health or abnormality, repetitive training and practice are necessary. We propose to develop a robotic medical education training simulator that would generate a realistic reflex behavior depending on the simulated reflex activity level selected when given a tendon tap assessment. This development was based on an existing ankle-foot simulator [5]. A modified sensing system is still under development. In this paper, a reflex model was developed to estimate the ankle reflexive torque based on the input tap force. This reflex model prediction was validated in simulation and then implemented into our robotic simulator prototype. Preliminary benchtop results demonstrated that our simulator was able to accurately deliver the reflexive torque pattern required to simulate the clinical reflex movement to the trainee.\",\"PeriodicalId\":236105,\"journal\":{\"name\":\"2022 Design of Medical Devices Conference\",\"volume\":\"83 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Design of Medical Devices Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/dmd2022-1072\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Design of Medical Devices Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2022-1072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

踝(或跟腱)腱反射通常在神经学检查中评估。临床实习医师要掌握正确的跟腱反射评估技术,并能够区分各种反映健康或异常的反射活动水平,需要反复的训练和练习。我们建议开发一个机器人医学教育训练模拟器,该模拟器将根据给定肌腱拍打评估时选择的模拟反射活动水平产生真实的反射行为。这项研究是基于现有的踝足模拟器[5]。一种改进的传感系统仍在开发中。本文建立了基于输入抽头力的踝关节反射力矩估算模型。该反射模型预测在仿真中得到验证,然后在机器人模拟器原型中实现。初步的实验结果表明,我们的模拟器能够准确地向受训者提供模拟临床反射运动所需的反射扭矩模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Control Design and Preliminary Evaluation of a Medical Education Simulator for Ankle Tendon Reflex Assessment Training
Ankle (or Achilles) tendon reflex is commonly assessed in a neurological examination. For a clinician trainee to master the correct assessment technique of Achilles tendon reflex and to be able to distinguish among various reflex activity levels indicating health or abnormality, repetitive training and practice are necessary. We propose to develop a robotic medical education training simulator that would generate a realistic reflex behavior depending on the simulated reflex activity level selected when given a tendon tap assessment. This development was based on an existing ankle-foot simulator [5]. A modified sensing system is still under development. In this paper, a reflex model was developed to estimate the ankle reflexive torque based on the input tap force. This reflex model prediction was validated in simulation and then implemented into our robotic simulator prototype. Preliminary benchtop results demonstrated that our simulator was able to accurately deliver the reflexive torque pattern required to simulate the clinical reflex movement to the trainee.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Communicating Cybersecurity and Privacy Design Attributes through Privacy Labeling of Consumer Electronic Medical Devices A Novel Tool for Auricle Retraction During Closure of Post-Auricular Incisions Development and Characterization of Biostable Hydrogel Robotic Actuators for Implantable Devices: Tendon Actuated Gelatin Non-Invasive Diagnosis of Deep Vein Thrombosis to Expedite Treatment and Prevent Pulmonary Embolism During Gestation Development of an Epicardial Mapping Tank for Noninvasive Electrical Mapping of Ex Vivo Large Mammalian Hearts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1