无源滤波器和有源滤波器在配电系统中的降谐波性能

M. Izhar, C. M. Hadzer, M. Syafrudin, S. Taib, S. Idris
{"title":"无源滤波器和有源滤波器在配电系统中的降谐波性能","authors":"M. Izhar, C. M. Hadzer, M. Syafrudin, S. Taib, S. Idris","doi":"10.1109/PECON.2004.1461625","DOIUrl":null,"url":null,"abstract":"This paper presents the results for the performance of passive and active power filter to reduce harmonics in the distribution system. The harmonics analysis is performed in order to observe the percentage reduction of amplitude current harmonics and total harmonic distortion for passive and active power filter at various loads. In addition to that the bidirectional switching is used as a strategy control in active power filter. Representative result of circuit simulations is carried out. The results show that the active power filter can simultaneously attenuate various frequencies and are compared with passive filter which is only filtering an individual harmonics. Also, the significant percentage of reduction for the amplitude current harmonics and total harmonic distortion by active power filter are compared to passive filter. Furthermore, the sinusoidal current waveform quality at distribution lines which filtered by active power filter is better compared with passive filter. Therefore, the active power filter is good to reduce harmonics in the electrical distribution systems.","PeriodicalId":375856,"journal":{"name":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"71","resultStr":"{\"title\":\"Performance for passive and active power filter in reducing harmonics in the distribution system\",\"authors\":\"M. Izhar, C. M. Hadzer, M. Syafrudin, S. Taib, S. Idris\",\"doi\":\"10.1109/PECON.2004.1461625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the results for the performance of passive and active power filter to reduce harmonics in the distribution system. The harmonics analysis is performed in order to observe the percentage reduction of amplitude current harmonics and total harmonic distortion for passive and active power filter at various loads. In addition to that the bidirectional switching is used as a strategy control in active power filter. Representative result of circuit simulations is carried out. The results show that the active power filter can simultaneously attenuate various frequencies and are compared with passive filter which is only filtering an individual harmonics. Also, the significant percentage of reduction for the amplitude current harmonics and total harmonic distortion by active power filter are compared to passive filter. Furthermore, the sinusoidal current waveform quality at distribution lines which filtered by active power filter is better compared with passive filter. Therefore, the active power filter is good to reduce harmonics in the electrical distribution systems.\",\"PeriodicalId\":375856,\"journal\":{\"name\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"71\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2004.1461625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2004.1461625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 71

摘要

本文介绍了无源滤波器和有源滤波器在配电系统中降低谐波的性能结果。为了观察无源和有源电力滤波器在不同负载下的幅值电流谐波和总谐波失真的减少百分比,进行了谐波分析。此外,在有源电力滤波器中还采用双向开关作为策略控制。给出了具有代表性的电路仿真结果。结果表明,有源滤波器可以同时衰减各种频率,并与只滤波单个谐波的无源滤波器进行了比较。此外,与无源滤波器相比,有源滤波器对幅值电流谐波和总谐波失真的降低率显著。此外,与无源滤波器相比,经有源滤波器滤波后的配电线路正弦电流波形质量更好。因此,有源电力滤波器对降低配电系统的谐波有很好的作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance for passive and active power filter in reducing harmonics in the distribution system
This paper presents the results for the performance of passive and active power filter to reduce harmonics in the distribution system. The harmonics analysis is performed in order to observe the percentage reduction of amplitude current harmonics and total harmonic distortion for passive and active power filter at various loads. In addition to that the bidirectional switching is used as a strategy control in active power filter. Representative result of circuit simulations is carried out. The results show that the active power filter can simultaneously attenuate various frequencies and are compared with passive filter which is only filtering an individual harmonics. Also, the significant percentage of reduction for the amplitude current harmonics and total harmonic distortion by active power filter are compared to passive filter. Furthermore, the sinusoidal current waveform quality at distribution lines which filtered by active power filter is better compared with passive filter. Therefore, the active power filter is good to reduce harmonics in the electrical distribution systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of improved genetic algorithms for loss minimisation in power system Implementation of different passive filter designs for harmonic mitigation A new single-phase two-wire hybrid active power filter using extension p-q theorem for photovoltaic application Voltage stability based weak area clustering technique in power system Calculation of static thrust on a linear DC actuator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1