{"title":"额定5kv及以上直流高直流试验电压直流屏蔽电力电缆系统现场试验指南","authors":"","doi":"10.1109/IEEESTD.2022.9721218","DOIUrl":null,"url":null,"abstract":"The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, insulated power cable systems rated 5 kV and above for dc service are presented in this guide. It applies to all types of power cable systems used for transmission of dc voltages and can include laminated or extruded cables designed for dc service. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.","PeriodicalId":377171,"journal":{"name":"IEEE Std 400.5-2021","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"IEEE Guide for Field Testing of DC Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Test Voltages\",\"authors\":\"\",\"doi\":\"10.1109/IEEESTD.2022.9721218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, insulated power cable systems rated 5 kV and above for dc service are presented in this guide. It applies to all types of power cable systems used for transmission of dc voltages and can include laminated or extruded cables designed for dc service. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.\",\"PeriodicalId\":377171,\"journal\":{\"name\":\"IEEE Std 400.5-2021\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Std 400.5-2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEEESTD.2022.9721218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Std 400.5-2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEEESTD.2022.9721218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
IEEE Guide for Field Testing of DC Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Test Voltages
The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, insulated power cable systems rated 5 kV and above for dc service are presented in this guide. It applies to all types of power cable systems used for transmission of dc voltages and can include laminated or extruded cables designed for dc service. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.