不同电源电压条件下并联有源滤波器控制策略的评价

N. Zaveri, A. Chudasama
{"title":"不同电源电压条件下并联有源滤波器控制策略的评价","authors":"N. Zaveri, A. Chudasama","doi":"10.1109/ISET-INDIA.2011.6145398","DOIUrl":null,"url":null,"abstract":"This paper focuses on the various control techniques of reference current generation for harmonic mitigation with a view to the problem of source current harmonics caused by the non-linear loads. All the techniques are analyzed mathematically and simulation results are compared in terms of compensation performance under different supply voltage conditions. Control strategies analyzed are the Instantaneous power theory, Symmetrical current component theory and an improved d-q theory. Simulation results are obtained under sinusoidal voltage source condition and distorted source voltage condition with voltage source convertor. The comparison and effectiveness of all the methods are based on the mathematical and theoretical analysis. Simulation results have been obtained with MATLAB employing a three phase three wire test system.","PeriodicalId":265646,"journal":{"name":"ISGT2011-India","volume":"189 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Evaluation of control strategies for parallel active filter under different supply voltage conditions\",\"authors\":\"N. Zaveri, A. Chudasama\",\"doi\":\"10.1109/ISET-INDIA.2011.6145398\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on the various control techniques of reference current generation for harmonic mitigation with a view to the problem of source current harmonics caused by the non-linear loads. All the techniques are analyzed mathematically and simulation results are compared in terms of compensation performance under different supply voltage conditions. Control strategies analyzed are the Instantaneous power theory, Symmetrical current component theory and an improved d-q theory. Simulation results are obtained under sinusoidal voltage source condition and distorted source voltage condition with voltage source convertor. The comparison and effectiveness of all the methods are based on the mathematical and theoretical analysis. Simulation results have been obtained with MATLAB employing a three phase three wire test system.\",\"PeriodicalId\":265646,\"journal\":{\"name\":\"ISGT2011-India\",\"volume\":\"189 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISGT2011-India\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISET-INDIA.2011.6145398\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISGT2011-India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISET-INDIA.2011.6145398","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

针对非线性负载引起的源电流谐波问题,重点介绍了各种谐波缓解参考电流产生的控制技术。对各种补偿方法进行了数学分析,并对不同电压条件下的补偿效果进行了仿真比较。分析的控制策略有瞬时功率理论、对称电流分量理论和改进的d-q理论。用电压源变换器分别在正弦电压源和畸变电压源两种情况下进行了仿真。在数学和理论分析的基础上,对各种方法进行了比较和有效性分析。利用MATLAB对三相三线测试系统进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of control strategies for parallel active filter under different supply voltage conditions
This paper focuses on the various control techniques of reference current generation for harmonic mitigation with a view to the problem of source current harmonics caused by the non-linear loads. All the techniques are analyzed mathematically and simulation results are compared in terms of compensation performance under different supply voltage conditions. Control strategies analyzed are the Instantaneous power theory, Symmetrical current component theory and an improved d-q theory. Simulation results are obtained under sinusoidal voltage source condition and distorted source voltage condition with voltage source convertor. The comparison and effectiveness of all the methods are based on the mathematical and theoretical analysis. Simulation results have been obtained with MATLAB employing a three phase three wire test system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improvement of demand response using mixed pumped storage hydro plant A new expression for power factor under nonsinusoidal conditions A reformed capacity subscription market in restructured power systems Smart grid implementation across the globe: A survey Enhancement of voltage stability index of distribution system by network reconfiguration including static load model and daily load curve
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1