测量系统噪声系数和增益对1ghz以上发射测量的影响

W. Atchison
{"title":"测量系统噪声系数和增益对1ghz以上发射测量的影响","authors":"W. Atchison","doi":"10.1109/ISEMC.2003.1236620","DOIUrl":null,"url":null,"abstract":"The ability to make weak signal emissions measurements at frequencies above 1 GHz id directly related to system noise figure, which ultimately sets the system noise floor. Contributing factors to the measurement system noise figure are the front-end coax loss, preamplifier noise figure, preamplifier gain, measurement device (spectrum analyzer or receiver) noise figure and measurement system configuration. Attention to the effects of these factors on EMC measurements is generally not understood. The system noise floor will have a major impact on the ability to detect and measure a weak signal. Impact on other factors, such as the introduction of intermodulation products by the preamplifier is not discussed in this paper.","PeriodicalId":359422,"journal":{"name":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Impact of measurement system noise figure and gain on emissions measurements above 1 GHz\",\"authors\":\"W. Atchison\",\"doi\":\"10.1109/ISEMC.2003.1236620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ability to make weak signal emissions measurements at frequencies above 1 GHz id directly related to system noise figure, which ultimately sets the system noise floor. Contributing factors to the measurement system noise figure are the front-end coax loss, preamplifier noise figure, preamplifier gain, measurement device (spectrum analyzer or receiver) noise figure and measurement system configuration. Attention to the effects of these factors on EMC measurements is generally not understood. The system noise floor will have a major impact on the ability to detect and measure a weak signal. Impact on other factors, such as the introduction of intermodulation products by the preamplifier is not discussed in this paper.\",\"PeriodicalId\":359422,\"journal\":{\"name\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2003.1236620\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2003.1236620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在1 GHz以上频率下进行微弱信号发射测量的能力与系统噪声系数直接相关,最终确定系统噪声底限。影响测量系统噪声系数的因素有前端同轴损耗、前置放大器噪声系数、前置放大器增益、测量设备(频谱分析仪或接收机)噪声系数和测量系统配置。人们通常不了解这些因素对电磁兼容测量的影响。系统本底噪声将对检测和测量微弱信号的能力产生重大影响。对其他因素的影响,如前置放大器引入互调产物,在本文中没有讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of measurement system noise figure and gain on emissions measurements above 1 GHz
The ability to make weak signal emissions measurements at frequencies above 1 GHz id directly related to system noise figure, which ultimately sets the system noise floor. Contributing factors to the measurement system noise figure are the front-end coax loss, preamplifier noise figure, preamplifier gain, measurement device (spectrum analyzer or receiver) noise figure and measurement system configuration. Attention to the effects of these factors on EMC measurements is generally not understood. The system noise floor will have a major impact on the ability to detect and measure a weak signal. Impact on other factors, such as the introduction of intermodulation products by the preamplifier is not discussed in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling of gapped power bus structures for isolation using cavity modes Electromagnetic coupling through perforated shields due to near field radiators Radiated electromagnetic fields of actual devices measured in different test environments Assessing loaded reverberation chambers: calculating threshold metrics Selection of cables and connectors for 100BaseTX Ethernet for defense/aerospace environment EMI compliance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1