{"title":"[物象不等。51例单侧假性晶状体的临床研究及实际应用[j]。","authors":"M Boissonnot, J F Risse, P Ingrand","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The subjective aniseiconia was measured with spatial eiconometer on 51 isometropic and unilateral pseudophakic patients in relation with the post-operative anisometropia. The median value of subjective aniseiconia is 2-3% for anisometropia minus or equal to 5 diopters, without statistic correlation, related to a probably \"sensorial brain adaptation\". So error of intra-ocular lens power calculation less than 7.5 diopters may be accepted.</p>","PeriodicalId":77584,"journal":{"name":"Ophtalmologie : organe de la Societe francaise d'ophtalmologie","volume":"4 2","pages":"213-4"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Aniseikonia. A clinical study of 51 unilateral pseudophakic patients and practical applications].\",\"authors\":\"M Boissonnot, J F Risse, P Ingrand\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The subjective aniseiconia was measured with spatial eiconometer on 51 isometropic and unilateral pseudophakic patients in relation with the post-operative anisometropia. The median value of subjective aniseiconia is 2-3% for anisometropia minus or equal to 5 diopters, without statistic correlation, related to a probably \\\"sensorial brain adaptation\\\". So error of intra-ocular lens power calculation less than 7.5 diopters may be accepted.</p>\",\"PeriodicalId\":77584,\"journal\":{\"name\":\"Ophtalmologie : organe de la Societe francaise d'ophtalmologie\",\"volume\":\"4 2\",\"pages\":\"213-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophtalmologie : organe de la Societe francaise d'ophtalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophtalmologie : organe de la Societe francaise d'ophtalmologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Aniseikonia. A clinical study of 51 unilateral pseudophakic patients and practical applications].
The subjective aniseiconia was measured with spatial eiconometer on 51 isometropic and unilateral pseudophakic patients in relation with the post-operative anisometropia. The median value of subjective aniseiconia is 2-3% for anisometropia minus or equal to 5 diopters, without statistic correlation, related to a probably "sensorial brain adaptation". So error of intra-ocular lens power calculation less than 7.5 diopters may be accepted.