{"title":"感应电机定子绕组匝故障检测","authors":"H. Kapeller, C. Kral, F. Pirker, G. Pascoli","doi":"10.1109/DEMPED.2005.4662513","DOIUrl":null,"url":null,"abstract":"Stator winding failures are a serious problem of induction machines. In the case of bearing failures or rotor faults, fault-specific signatures increase slowly. An induction machine with such failures still can be operated for a certain time without taking strict precautions. Stator faults may occur much faster due to insulation breakdown or overload and are therefore more critical with respect to time. This paper presents measurement results of an accidentally arising stator winding fault, which was recorded during the investigation of stator asymmetries. Furthermore, an on-line fault detection technique as well as some measurement data applied to this technique, are presented. The used technique is based on extracting a so called injected negative sequence current.","PeriodicalId":230148,"journal":{"name":"2005 5th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"325 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Stator winding turn fault detection for induction machines\",\"authors\":\"H. Kapeller, C. Kral, F. Pirker, G. Pascoli\",\"doi\":\"10.1109/DEMPED.2005.4662513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stator winding failures are a serious problem of induction machines. In the case of bearing failures or rotor faults, fault-specific signatures increase slowly. An induction machine with such failures still can be operated for a certain time without taking strict precautions. Stator faults may occur much faster due to insulation breakdown or overload and are therefore more critical with respect to time. This paper presents measurement results of an accidentally arising stator winding fault, which was recorded during the investigation of stator asymmetries. Furthermore, an on-line fault detection technique as well as some measurement data applied to this technique, are presented. The used technique is based on extracting a so called injected negative sequence current.\",\"PeriodicalId\":230148,\"journal\":{\"name\":\"2005 5th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"volume\":\"325 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 5th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2005.4662513\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 5th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2005.4662513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

定子绕组故障是感应电机的一个严重问题。在轴承故障或转子故障的情况下,故障特定特征增加缓慢。有这种故障的感应电机,在不采取严格预防措施的情况下,仍然可以运行一段时间。由于绝缘击穿或过载,定子故障可能发生得更快,因此就时间而言更为关键。本文介绍了在对定子绕组不对称现象进行研究时,记录的一次偶然发生的定子绕组故障的测量结果。此外,还介绍了一种在线故障检测技术以及应用于该技术的一些测量数据。所使用的技术是基于提取所谓的注入负序电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stator winding turn fault detection for induction machines
Stator winding failures are a serious problem of induction machines. In the case of bearing failures or rotor faults, fault-specific signatures increase slowly. An induction machine with such failures still can be operated for a certain time without taking strict precautions. Stator faults may occur much faster due to insulation breakdown or overload and are therefore more critical with respect to time. This paper presents measurement results of an accidentally arising stator winding fault, which was recorded during the investigation of stator asymmetries. Furthermore, an on-line fault detection technique as well as some measurement data applied to this technique, are presented. The used technique is based on extracting a so called injected negative sequence current.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of parameter and sensing errors on DTC IM drive operation Electromagnetic flux-based condition monitoring for electrical machines Location of inter-turn short circuit in linear induction motor by dc measurement Mathematical modelling of commutator DC motor in failure conditions Test-bed system for improved induction machines diagnostics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1