UV-C LED布置对流动反应器中大肠杆菌杀菌效果的研究

Chien-Ping Wang, Jun Liao
{"title":"UV-C LED布置对流动反应器中大肠杆菌杀菌效果的研究","authors":"Chien-Ping Wang, Jun Liao","doi":"10.11159/icepr23.121","DOIUrl":null,"url":null,"abstract":"Extended Abstract In this study, a planar UV reactor with distinct UV-C LED arrangements was proposed to treat potable water. The particle tracing method combined with computational fluid dynamics were used to simulate water velocity field, microbial trajectory and exposure time. The ray tracing method was used to determine the irradiance distribution in water. The simulated variables were integrated to determine the distribution of fluence in water. UV light has been widely used in water sterilization processes because it is safe and simple and does not produce any unwanted by-products [1]. UV-C LEDs have been used instead of mercury lamps in water disinfection processes because of their numerous advantages, such as their long lifespan, mercury-free design, tunable wavelength, and high design flexibility [2,3]. The arrangement of UV-C LEDs substantially affects the light distribution and UV fluence to which microbes are subjected. However, if the distribution of light is not optimized, the performance of reactors employing UV LEDs may be lower than that of reactors employing traditional mercury lamps [4] . According to studies on the application of UV-C LEDs in water disinfection in flow reactors, positively correlating the flow field with the irradiation distribution can aid in the design of highly efficient UV reactors. In this study, the effects of LED arrangement on the efficacy of a planar UV LED reactor for E. coli disinfection under various flow rates were investigated. In this experiment, E. coli IFO 3301 was used to validate the water disinfection performance of the reactor. The bacteria were cultured on NZCYM broth supplemented with deionized water and grown in an incubator. To determine the reactor’s sterilization performance, plate counting was","PeriodicalId":398088,"journal":{"name":"Proceedings of the 9th World Congress on New Technologies","volume":"325 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The investigation of UV-C LED arrangement on the sterilization of Escherichia coli in flow reactors\",\"authors\":\"Chien-Ping Wang, Jun Liao\",\"doi\":\"10.11159/icepr23.121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Extended Abstract In this study, a planar UV reactor with distinct UV-C LED arrangements was proposed to treat potable water. The particle tracing method combined with computational fluid dynamics were used to simulate water velocity field, microbial trajectory and exposure time. The ray tracing method was used to determine the irradiance distribution in water. The simulated variables were integrated to determine the distribution of fluence in water. UV light has been widely used in water sterilization processes because it is safe and simple and does not produce any unwanted by-products [1]. UV-C LEDs have been used instead of mercury lamps in water disinfection processes because of their numerous advantages, such as their long lifespan, mercury-free design, tunable wavelength, and high design flexibility [2,3]. The arrangement of UV-C LEDs substantially affects the light distribution and UV fluence to which microbes are subjected. However, if the distribution of light is not optimized, the performance of reactors employing UV LEDs may be lower than that of reactors employing traditional mercury lamps [4] . According to studies on the application of UV-C LEDs in water disinfection in flow reactors, positively correlating the flow field with the irradiation distribution can aid in the design of highly efficient UV reactors. In this study, the effects of LED arrangement on the efficacy of a planar UV LED reactor for E. coli disinfection under various flow rates were investigated. In this experiment, E. coli IFO 3301 was used to validate the water disinfection performance of the reactor. The bacteria were cultured on NZCYM broth supplemented with deionized water and grown in an incubator. To determine the reactor’s sterilization performance, plate counting was\",\"PeriodicalId\":398088,\"journal\":{\"name\":\"Proceedings of the 9th World Congress on New Technologies\",\"volume\":\"325 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 9th World Congress on New Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11159/icepr23.121\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 9th World Congress on New Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11159/icepr23.121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在这项研究中,提出了一个具有不同UV- c LED排列的平面UV反应器来处理饮用水。采用粒子示踪法结合计算流体力学模拟了水流速度场、微生物运动轨迹和暴露时间。采用射线追踪法测定了水中的辐照度分布。对模拟变量进行综合,以确定水中的通量分布。由于紫外线安全、简单,不会产生任何有害的副产物[1],因此在水杀菌过程中得到了广泛的应用。UV-C led因其寿命长、无汞设计、波长可调、设计灵活性高等诸多优点,已被用于水消毒过程中取代汞灯[2,3]。UV- c led的排列实质上影响了微生物所受的光分布和UV通量。然而,如果不优化光的分布,使用UV led的反应器的性能可能低于使用传统汞灯[4]的反应器。通过UV- c led在流动反应器水消毒中的应用研究,将流场与辐照分布正相关,有助于高效UV反应器的设计。本研究考察了LED排列方式对平面UV LED反应器在不同流速下对大肠杆菌消毒效果的影响。本实验采用大肠杆菌IFO 3301对反应器的水消毒性能进行验证。细菌在加去离子水的NZCYM肉汤中培养,并在培养箱中生长。为了确定反应器的灭菌性能,进行了平板计数
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The investigation of UV-C LED arrangement on the sterilization of Escherichia coli in flow reactors
Extended Abstract In this study, a planar UV reactor with distinct UV-C LED arrangements was proposed to treat potable water. The particle tracing method combined with computational fluid dynamics were used to simulate water velocity field, microbial trajectory and exposure time. The ray tracing method was used to determine the irradiance distribution in water. The simulated variables were integrated to determine the distribution of fluence in water. UV light has been widely used in water sterilization processes because it is safe and simple and does not produce any unwanted by-products [1]. UV-C LEDs have been used instead of mercury lamps in water disinfection processes because of their numerous advantages, such as their long lifespan, mercury-free design, tunable wavelength, and high design flexibility [2,3]. The arrangement of UV-C LEDs substantially affects the light distribution and UV fluence to which microbes are subjected. However, if the distribution of light is not optimized, the performance of reactors employing UV LEDs may be lower than that of reactors employing traditional mercury lamps [4] . According to studies on the application of UV-C LEDs in water disinfection in flow reactors, positively correlating the flow field with the irradiation distribution can aid in the design of highly efficient UV reactors. In this study, the effects of LED arrangement on the efficacy of a planar UV LED reactor for E. coli disinfection under various flow rates were investigated. In this experiment, E. coli IFO 3301 was used to validate the water disinfection performance of the reactor. The bacteria were cultured on NZCYM broth supplemented with deionized water and grown in an incubator. To determine the reactor’s sterilization performance, plate counting was
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Variable Effects of the COVID-19 Pandemic on Reported Adverse Events for Arrhythmic Activity and 30-Day Fills For Anti-Arrhythmic Agents Optimization Of Mercury Remediation From A Contaminated Industrial Park Soil Via Thermo Desorption: An Experimental Approach A Multi-Layer Perceptron Approach For Estimating Daily Surface NO2 In Thiruvananthapuram City Rehabilitation and Landscape Integration of a Tailings Deposit in Atacama, Chile Organic Contaminants Released Form Plastics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1