DSTATCOM在各种负载扰动下提高电能质量的实验实现

Pushpanjali Shadangi, S. D. Swain, P. K. Ray
{"title":"DSTATCOM在各种负载扰动下提高电能质量的实验实现","authors":"Pushpanjali Shadangi, S. D. Swain, P. K. Ray","doi":"10.1109/ICEPE50861.2021.9404488","DOIUrl":null,"url":null,"abstract":"In this paper, a Modified Instantaneous Reactive Power Theory (MIRPT) is proposed for DSTATCOM to abolish harmonic current and indemnify the reactive power under various load perturbations. The DSTATCOM is the building blocks of voltage source inverter with a common DC-link capacitor and a hysteresis band current controller for switching pattern generation. In order to proof the efficacy of th proposed controller based DSTATCOM for three different case studies are considered and then simulated. All simulations are executed by using MATLAB 2016. DSTATCOM performance has been found more effective to compensate harmonics under all scenarios of load disorder.","PeriodicalId":250203,"journal":{"name":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Experimental realization of DSTATCOM for Power Quality Enhancement Under Various Load Perturbations\",\"authors\":\"Pushpanjali Shadangi, S. D. Swain, P. K. Ray\",\"doi\":\"10.1109/ICEPE50861.2021.9404488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a Modified Instantaneous Reactive Power Theory (MIRPT) is proposed for DSTATCOM to abolish harmonic current and indemnify the reactive power under various load perturbations. The DSTATCOM is the building blocks of voltage source inverter with a common DC-link capacitor and a hysteresis band current controller for switching pattern generation. In order to proof the efficacy of th proposed controller based DSTATCOM for three different case studies are considered and then simulated. All simulations are executed by using MATLAB 2016. DSTATCOM performance has been found more effective to compensate harmonics under all scenarios of load disorder.\",\"PeriodicalId\":250203,\"journal\":{\"name\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE50861.2021.9404488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE50861.2021.9404488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种修正的瞬时无功理论(MIRPT),用于DSTATCOM消除谐波电流,补偿各种负载扰动下的无功功率。DSTATCOM是电压源逆变器的构建模块,具有普通直流链路电容器和用于开关模式生成的滞后带电流控制器。为了证明所提出的基于DSTATCOM的控制器的有效性,考虑了三个不同的案例,然后进行了仿真。所有仿真均使用MATLAB 2016进行。在各种负载失谐情况下,DSTATCOM的性能都能有效地补偿谐波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental realization of DSTATCOM for Power Quality Enhancement Under Various Load Perturbations
In this paper, a Modified Instantaneous Reactive Power Theory (MIRPT) is proposed for DSTATCOM to abolish harmonic current and indemnify the reactive power under various load perturbations. The DSTATCOM is the building blocks of voltage source inverter with a common DC-link capacitor and a hysteresis band current controller for switching pattern generation. In order to proof the efficacy of th proposed controller based DSTATCOM for three different case studies are considered and then simulated. All simulations are executed by using MATLAB 2016. DSTATCOM performance has been found more effective to compensate harmonics under all scenarios of load disorder.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive Kernel Width fourth order Maximum Correntropy based VSC control of grid-tied PV-Battery System MRAS Based Sensorless PMSM Drive With Regenerative Braking For Solar PV-Battery Powered EV Design and FPGA Implementation of an Islanding Detection cum Re-synchronisation Technique for a Grid Connected Inverter in a DC Microgrid Delayed LMS Based Adaptive Control of PV-DSTATCOM System Sliding Mode Observer based Rotor Position Estimation with Field Oriented Control of PMBLDC Motor Drive
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1