M. Frivaldský, P. Drgona, B. Kozacek, M. Piri, M. Pridala
{"title":"关键部件的性能对供电机组的效率影响较大","authors":"M. Frivaldský, P. Drgona, B. Kozacek, M. Piri, M. Pridala","doi":"10.1109/ELEKTRO.2016.7512054","DOIUrl":null,"url":null,"abstract":"The paper deals with FoM parameter analysis of power semiconductor system's components. This parameter can be used as optimization tool of quality indicators for power supply systems. The main advantage of using FoM assessment technique for certain system's components is the elimination of simulation and physical experiments for effectivity evaluation. This paper consist of description of FoM assessment process for perspective converter structures, for various working conditions and the appropriateness of using this method is also verified by simulation experiments on models with high degree of validity. The relevancy of FoM parameter is finally evaluated in the way of efficiency (one of qualitative indicators) investigation of proposed LLC converter, where also different materials of core transformers have been verified, as well as their influence on the efficiency.","PeriodicalId":369251,"journal":{"name":"2016 ELEKTRO","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Critical component's figure of merite influence on power supply unit efficiency\",\"authors\":\"M. Frivaldský, P. Drgona, B. Kozacek, M. Piri, M. Pridala\",\"doi\":\"10.1109/ELEKTRO.2016.7512054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with FoM parameter analysis of power semiconductor system's components. This parameter can be used as optimization tool of quality indicators for power supply systems. The main advantage of using FoM assessment technique for certain system's components is the elimination of simulation and physical experiments for effectivity evaluation. This paper consist of description of FoM assessment process for perspective converter structures, for various working conditions and the appropriateness of using this method is also verified by simulation experiments on models with high degree of validity. The relevancy of FoM parameter is finally evaluated in the way of efficiency (one of qualitative indicators) investigation of proposed LLC converter, where also different materials of core transformers have been verified, as well as their influence on the efficiency.\",\"PeriodicalId\":369251,\"journal\":{\"name\":\"2016 ELEKTRO\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 ELEKTRO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELEKTRO.2016.7512054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 ELEKTRO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELEKTRO.2016.7512054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文对功率半导体系统中各部件的FoM参数进行了分析。该参数可作为供电系统质量指标的优化工具。使用FoM评估技术对某些系统部件进行有效性评估的主要优点是消除了模拟和物理实验。本文描述了透视转化器结构在各种工况下的FoM评估过程,并通过模型的仿真实验验证了该方法的适用性,具有较高的有效性。最后通过对所提出的LLC变换器的效率(定性指标之一)的研究来评价FoM参数的相关性,并验证了铁心变压器的不同材料及其对效率的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Critical component's figure of merite influence on power supply unit efficiency
The paper deals with FoM parameter analysis of power semiconductor system's components. This parameter can be used as optimization tool of quality indicators for power supply systems. The main advantage of using FoM assessment technique for certain system's components is the elimination of simulation and physical experiments for effectivity evaluation. This paper consist of description of FoM assessment process for perspective converter structures, for various working conditions and the appropriateness of using this method is also verified by simulation experiments on models with high degree of validity. The relevancy of FoM parameter is finally evaluated in the way of efficiency (one of qualitative indicators) investigation of proposed LLC converter, where also different materials of core transformers have been verified, as well as their influence on the efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Linear features of robot servo-system controlled in sliding mode Patch antenna optimization in COMSOL multiphysics Mathematical model of electric energy losses calculating in crosslinked four-wire polyethylene insulated (XLPE) aerial bundled cables Research and development in collaboration with private sectors: Applications of electronics and computer technology in the fields of medical science, ergonomics and assistive technology Load torque impact on DC motor current control accuracy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1