基于模型的供热控制器的节能潜力:可行性研究

L. Ferkl, Clara Verhelst, L. Helsen, Alexandr Ciller, Dana Komarkova
{"title":"基于模型的供热控制器的节能潜力:可行性研究","authors":"L. Ferkl, Clara Verhelst, L. Helsen, Alexandr Ciller, Dana Komarkova","doi":"10.1109/CCA.2011.6044460","DOIUrl":null,"url":null,"abstract":"In order to provide decision-making mechanism for application of model-based control of heating systems in buildings, a method has been proposed that assumes the energy balance calculation as the performance bound for the model-based controller. If the performance bound is significantly lower than the actual energy consumption, a more accurate estimate is made by means of dynamic model identification and model-based controller simulation. Said method has been tested as a case study on a health care center located in Prague, Czech Republic.","PeriodicalId":208713,"journal":{"name":"2011 IEEE International Conference on Control Applications (CCA)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Energy savings potential of a model-based controller for heating: A feasibility study\",\"authors\":\"L. Ferkl, Clara Verhelst, L. Helsen, Alexandr Ciller, Dana Komarkova\",\"doi\":\"10.1109/CCA.2011.6044460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to provide decision-making mechanism for application of model-based control of heating systems in buildings, a method has been proposed that assumes the energy balance calculation as the performance bound for the model-based controller. If the performance bound is significantly lower than the actual energy consumption, a more accurate estimate is made by means of dynamic model identification and model-based controller simulation. Said method has been tested as a case study on a health care center located in Prague, Czech Republic.\",\"PeriodicalId\":208713,\"journal\":{\"name\":\"2011 IEEE International Conference on Control Applications (CCA)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Control Applications (CCA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCA.2011.6044460\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Control Applications (CCA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCA.2011.6044460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了给基于模型的建筑供暖系统控制的应用提供决策机制,提出了一种以能量平衡计算作为基于模型的控制器的性能界的方法。如果性能界限明显低于实际能耗,则通过动态模型识别和基于模型的控制器仿真来进行更准确的估计。该方法已在捷克共和国布拉格的一家卫生保健中心进行了案例研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Energy savings potential of a model-based controller for heating: A feasibility study
In order to provide decision-making mechanism for application of model-based control of heating systems in buildings, a method has been proposed that assumes the energy balance calculation as the performance bound for the model-based controller. If the performance bound is significantly lower than the actual energy consumption, a more accurate estimate is made by means of dynamic model identification and model-based controller simulation. Said method has been tested as a case study on a health care center located in Prague, Czech Republic.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Suppression of general decoherence in arbitrary n-level atom in Ξ-configuration under a bang-bang control Interval observer for Chlorella vulgaris culture in a photobioreactor Miniaturizing the spherical sundial: A hemispherical sensor for orientation and positioning with respect to point sources of light Robust gain-scheduled control of dc-dc converters: An LMI approach Slip measurement and vehicle control for leg/wheel mobile robots using caster type odometers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1