基于异常的电网故障检测技术

Mohammed Wadi, Wisam Elmasry
{"title":"基于异常的电网故障检测技术","authors":"Mohammed Wadi, Wisam Elmasry","doi":"10.1109/ICEPE-P51568.2021.9423479","DOIUrl":null,"url":null,"abstract":"In recent years, fault detection in electrical power systems has attracted substantial attention from both research communities and industry. Although many fault detection methods and their modifications have been developed during the past decade, it remained very challenging in real applications. Moreover, one of the most important parts of designing a fault detection system is reliable data for training and testing which is rare. Accordingly, this paper proposes an anomaly-based technique for fault detection in electrical power systems. Furthermore, a One-Class Support Vector Machine (SVM) model and a Principal Component Analysis (PCA)based model are utilized to accomplish the desired task. The used models are trained and tested on VSB (Technical University of Ostrava) Power Line Fault Detection dataset which is a large amount of real-time waveform data recorded by their meter on Kaggle. Finally, performance and Receiver Operating Characteristic (ROC) curves analyses of our results are exploited to verify the effectiveness of the proposed technique in the fault detection problem.","PeriodicalId":347169,"journal":{"name":"2021 International Conference on Electric Power Engineering – Palestine (ICEPE- P)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":"{\"title\":\"An Anomaly-based Technique for Fault Detection in Power System Networks\",\"authors\":\"Mohammed Wadi, Wisam Elmasry\",\"doi\":\"10.1109/ICEPE-P51568.2021.9423479\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, fault detection in electrical power systems has attracted substantial attention from both research communities and industry. Although many fault detection methods and their modifications have been developed during the past decade, it remained very challenging in real applications. Moreover, one of the most important parts of designing a fault detection system is reliable data for training and testing which is rare. Accordingly, this paper proposes an anomaly-based technique for fault detection in electrical power systems. Furthermore, a One-Class Support Vector Machine (SVM) model and a Principal Component Analysis (PCA)based model are utilized to accomplish the desired task. The used models are trained and tested on VSB (Technical University of Ostrava) Power Line Fault Detection dataset which is a large amount of real-time waveform data recorded by their meter on Kaggle. Finally, performance and Receiver Operating Characteristic (ROC) curves analyses of our results are exploited to verify the effectiveness of the proposed technique in the fault detection problem.\",\"PeriodicalId\":347169,\"journal\":{\"name\":\"2021 International Conference on Electric Power Engineering – Palestine (ICEPE- P)\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electric Power Engineering – Palestine (ICEPE- P)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE-P51568.2021.9423479\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electric Power Engineering – Palestine (ICEPE- P)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-P51568.2021.9423479","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

近年来,电力系统的故障检测受到了学术界和工业界的广泛关注。虽然在过去的十年中已经开发了许多故障检测方法及其改进,但在实际应用中仍然存在很大的挑战。此外,设计故障检测系统最重要的部分之一是可靠的训练和测试数据,而这些数据很少。为此,本文提出了一种基于异常的电力系统故障检测技术。此外,利用一类支持向量机(SVM)模型和基于主成分分析(PCA)的模型来完成期望的任务。使用的模型在VSB(俄斯特拉发技术大学)电力线故障检测数据集上进行训练和测试,该数据集是由他们的仪表在Kaggle上记录的大量实时波形数据。最后,利用我们的结果的性能和接收机工作特征(ROC)曲线分析来验证所提出的技术在故障检测问题中的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An Anomaly-based Technique for Fault Detection in Power System Networks
In recent years, fault detection in electrical power systems has attracted substantial attention from both research communities and industry. Although many fault detection methods and their modifications have been developed during the past decade, it remained very challenging in real applications. Moreover, one of the most important parts of designing a fault detection system is reliable data for training and testing which is rare. Accordingly, this paper proposes an anomaly-based technique for fault detection in electrical power systems. Furthermore, a One-Class Support Vector Machine (SVM) model and a Principal Component Analysis (PCA)based model are utilized to accomplish the desired task. The used models are trained and tested on VSB (Technical University of Ostrava) Power Line Fault Detection dataset which is a large amount of real-time waveform data recorded by their meter on Kaggle. Finally, performance and Receiver Operating Characteristic (ROC) curves analyses of our results are exploited to verify the effectiveness of the proposed technique in the fault detection problem.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hybrid energy system for Dier El Balah quarantine center in Gaza Strip, Palestine Sliding Mode Control of AC/DC Bridgeless Converter using Piezoelectric Energy Harvesting System Performance Comparison of Different Manufacturers Solar PV Modules Used in Gaza Strip The Effect of Tilting a PV Array by Monthly or Seasonal Optimal Tilt Angles on Energy Yield of a Solar PV System A Low-cost Solar System for Freezers without Back-up Batteries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1