{"title":"对底部安装的Aanderaa RDCP600与RDI Workhorse 600 ADCP,以及系泊的Aanderaa RCM9 MKII电流计进行了现场对比测试","authors":"N. Pettigrew, J. Wallinga, R. Fleming","doi":"10.1109/CCM.2005.1506331","DOIUrl":null,"url":null,"abstract":"Detailed field testing of a bottom-mounted Aanderaa RDCP600 Doppler profiler was conducted at a protected coastal embayment. The RDCP600 was compared for 30 days to a string of seven moored Aanderaa RCM9 MKII in situ Doppler current meters, and an RDI 600 kHz workhorse ADCP. The test buoy was equipped with outriggers to allow measurements very close to the surface and to examine the acoustic and wake effects of the buoy on the performance of the RCM9 standard. The two 600 kHz Doppler profilers were deployed on the same bottom frame in order to ensure the same tilt and distance (approximately 50 m) from the moored RCM9 current meters. The Doppler profilers were programmed to sample during alternating time windows within a 20-minute sampling interval in order to avoid acoustic cross talk and interference. A common time base was achieved via post-deployment linear interpolation. Results of vector correlations and difference statistics show excellent agreement between all of the current measurement devices. Mean differences were generally less than 0.005 m s' and the RMS differences were on the order of 0.02 m s/sup -1/.","PeriodicalId":264883,"journal":{"name":"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Field comparison tests of a bottom-mounted Aanderaa RDCP600 with an RDI Workhorse 600 ADCP, and a moored string of Aanderaa RCM9 MKII current meters\",\"authors\":\"N. Pettigrew, J. Wallinga, R. Fleming\",\"doi\":\"10.1109/CCM.2005.1506331\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Detailed field testing of a bottom-mounted Aanderaa RDCP600 Doppler profiler was conducted at a protected coastal embayment. The RDCP600 was compared for 30 days to a string of seven moored Aanderaa RCM9 MKII in situ Doppler current meters, and an RDI 600 kHz workhorse ADCP. The test buoy was equipped with outriggers to allow measurements very close to the surface and to examine the acoustic and wake effects of the buoy on the performance of the RCM9 standard. The two 600 kHz Doppler profilers were deployed on the same bottom frame in order to ensure the same tilt and distance (approximately 50 m) from the moored RCM9 current meters. The Doppler profilers were programmed to sample during alternating time windows within a 20-minute sampling interval in order to avoid acoustic cross talk and interference. A common time base was achieved via post-deployment linear interpolation. Results of vector correlations and difference statistics show excellent agreement between all of the current measurement devices. Mean differences were generally less than 0.005 m s' and the RMS differences were on the order of 0.02 m s/sup -1/.\",\"PeriodicalId\":264883,\"journal\":{\"name\":\"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCM.2005.1506331\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE/OES Eighth Working Conference on Current Measurement Technology, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCM.2005.1506331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
对Aanderaa RDCP600型海底多普勒剖面仪进行了详细的现场测试。将RDCP600与7个系泊的Aanderaa RCM9 MKII原位多普勒电流计和RDI 600 kHz主力ADCP进行了30天的比较。测试浮标配备了外伸臂,可以非常接近水面进行测量,并检查浮标对RCM9标准性能的声学和尾流影响。两个600 kHz多普勒分析器部署在同一个底部框架上,以确保与系泊的RCM9电流计保持相同的倾斜度和距离(约50米)。为了避免声串扰和干扰,多普勒谱仪被编程为在20分钟采样间隔内的交替时间窗进行采样。通过部署后的线性插值实现了一个共同的时间基础。矢量相关和差异统计的结果表明,目前所有的测量设备之间的一致性很好。平均差值一般小于0.005 m s’,均方根差值约为0.02 m s/sup -1/。
Field comparison tests of a bottom-mounted Aanderaa RDCP600 with an RDI Workhorse 600 ADCP, and a moored string of Aanderaa RCM9 MKII current meters
Detailed field testing of a bottom-mounted Aanderaa RDCP600 Doppler profiler was conducted at a protected coastal embayment. The RDCP600 was compared for 30 days to a string of seven moored Aanderaa RCM9 MKII in situ Doppler current meters, and an RDI 600 kHz workhorse ADCP. The test buoy was equipped with outriggers to allow measurements very close to the surface and to examine the acoustic and wake effects of the buoy on the performance of the RCM9 standard. The two 600 kHz Doppler profilers were deployed on the same bottom frame in order to ensure the same tilt and distance (approximately 50 m) from the moored RCM9 current meters. The Doppler profilers were programmed to sample during alternating time windows within a 20-minute sampling interval in order to avoid acoustic cross talk and interference. A common time base was achieved via post-deployment linear interpolation. Results of vector correlations and difference statistics show excellent agreement between all of the current measurement devices. Mean differences were generally less than 0.005 m s' and the RMS differences were on the order of 0.02 m s/sup -1/.