{"title":"管道针孔定位方法的比较","authors":"K. Watanabe, M. Kakishima, K. Yokoyama","doi":"10.1109/IMTC.1994.351983","DOIUrl":null,"url":null,"abstract":"Here, we compare the two acoustic methods named cross-correlation and auto-correlation to locate pinhole locations in a gas-pipeline. The cross-correlation method that determines the location from the cross-correlation of two acoustic signals detected at two terminals of the pipeline is effective for pipelines with greater acoustic damping. Whereas the auto-correlation method that determines the location from the auto-correlation of the acoustic signal detected at one terminal of the pipeline is effective for those with less acoustic damping.<<ETX>>","PeriodicalId":231484,"journal":{"name":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","volume":"50 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A comparison of location methods for pinholes in pipelines\",\"authors\":\"K. Watanabe, M. Kakishima, K. Yokoyama\",\"doi\":\"10.1109/IMTC.1994.351983\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Here, we compare the two acoustic methods named cross-correlation and auto-correlation to locate pinhole locations in a gas-pipeline. The cross-correlation method that determines the location from the cross-correlation of two acoustic signals detected at two terminals of the pipeline is effective for pipelines with greater acoustic damping. Whereas the auto-correlation method that determines the location from the auto-correlation of the acoustic signal detected at one terminal of the pipeline is effective for those with less acoustic damping.<<ETX>>\",\"PeriodicalId\":231484,\"journal\":{\"name\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"volume\":\"50 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1994.351983\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1994.351983","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A comparison of location methods for pinholes in pipelines
Here, we compare the two acoustic methods named cross-correlation and auto-correlation to locate pinhole locations in a gas-pipeline. The cross-correlation method that determines the location from the cross-correlation of two acoustic signals detected at two terminals of the pipeline is effective for pipelines with greater acoustic damping. Whereas the auto-correlation method that determines the location from the auto-correlation of the acoustic signal detected at one terminal of the pipeline is effective for those with less acoustic damping.<>