电源模块局部放电定位的基础研究

H. Mitsudome, Yuuya Akinaga, K. Matsuo, M. Kozako, M. Hikita, Y. Ikeda, K. Taniguchi, Y. Nakamura, K. Okamoto
{"title":"电源模块局部放电定位的基础研究","authors":"H. Mitsudome, Yuuya Akinaga, K. Matsuo, M. Kozako, M. Hikita, Y. Ikeda, K. Taniguchi, Y. Nakamura, K. Okamoto","doi":"10.1109/ICD.2016.7547640","DOIUrl":null,"url":null,"abstract":"This paper deals with partial discharge (PD) location in a power module by measuring electromagnetic (EM) wave of PD using four loop sensors. As the distance between the sensor and PD source decreases, the peak to peak magnitude of the first wave of detected EM wave was found to increase using four sensors array. An attempt is made to locate PD source using output electromagnetic waves detected four loop sensors by the time of flight method. As a result, the present method is found to allow PD location with location identification error of 5 mm.","PeriodicalId":306397,"journal":{"name":"2016 IEEE International Conference on Dielectrics (ICD)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Basic study on partial discharge location in power module\",\"authors\":\"H. Mitsudome, Yuuya Akinaga, K. Matsuo, M. Kozako, M. Hikita, Y. Ikeda, K. Taniguchi, Y. Nakamura, K. Okamoto\",\"doi\":\"10.1109/ICD.2016.7547640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with partial discharge (PD) location in a power module by measuring electromagnetic (EM) wave of PD using four loop sensors. As the distance between the sensor and PD source decreases, the peak to peak magnitude of the first wave of detected EM wave was found to increase using four sensors array. An attempt is made to locate PD source using output electromagnetic waves detected four loop sensors by the time of flight method. As a result, the present method is found to allow PD location with location identification error of 5 mm.\",\"PeriodicalId\":306397,\"journal\":{\"name\":\"2016 IEEE International Conference on Dielectrics (ICD)\",\"volume\":\"41 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Dielectrics (ICD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICD.2016.7547640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Dielectrics (ICD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICD.2016.7547640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文利用四回路传感器测量功率模块局部放电的电磁波,研究了局部放电的定位问题。随着传感器与PD源距离的减小,四个传感器阵列所探测到的电磁波第一波的峰对峰幅度增大。尝试利用飞行时间法检测四回路传感器的输出电磁波来定位局部放电源。结果表明,本方法可以实现PD定位,定位识别误差为5mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Basic study on partial discharge location in power module
This paper deals with partial discharge (PD) location in a power module by measuring electromagnetic (EM) wave of PD using four loop sensors. As the distance between the sensor and PD source decreases, the peak to peak magnitude of the first wave of detected EM wave was found to increase using four sensors array. An attempt is made to locate PD source using output electromagnetic waves detected four loop sensors by the time of flight method. As a result, the present method is found to allow PD location with location identification error of 5 mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characteristics of g3 - an alternative to SF6 Self-healing electrical insulation systems Aging behaviour of dodecylbenzene in the presence of copper and dibenzyl disulfide (DBDS) Electrical treeing behavior in XLPE under kHz-AC voltage Single partial discharge in nonuniform electric field for different polymer dielectrics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1