Weiqing Tao, Cheng Fang, Shengqing Lu, Qingsong Liu, Ruixing Lin
{"title":"光伏发电系统配电网电压控制","authors":"Weiqing Tao, Cheng Fang, Shengqing Lu, Qingsong Liu, Ruixing Lin","doi":"10.1109/IGBSG.2018.8393571","DOIUrl":null,"url":null,"abstract":"A voltage control system composed of grid-connected photovoltaic (PV) inverters and on-load tap changing transformer (OLTC) is proposed to solve the voltage limit problem arisen from high-penetration distributed PV power generation system integrated into the distribution network. PV inverters, as a part of grid voltage control system, are able to control the reactive power based on the voltage amplitude. In the case when PV inverters failed to normalize the grid voltage, OLTC tap controller is used as an alternative. In this case, the tap of OLTC tap controller will change accordingly based on the maximum and minimum voltage estimated from phasor measurement unit (PMU) placed at key nodes in the grid. The validity of the voltage control system proposed in this paper is verified by detailed simulation and solid results.","PeriodicalId":356367,"journal":{"name":"2018 3rd International Conference on Intelligent Green Building and Smart Grid (IGBSG)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Voltage control of distribution network with photovoltaic power generation systems\",\"authors\":\"Weiqing Tao, Cheng Fang, Shengqing Lu, Qingsong Liu, Ruixing Lin\",\"doi\":\"10.1109/IGBSG.2018.8393571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A voltage control system composed of grid-connected photovoltaic (PV) inverters and on-load tap changing transformer (OLTC) is proposed to solve the voltage limit problem arisen from high-penetration distributed PV power generation system integrated into the distribution network. PV inverters, as a part of grid voltage control system, are able to control the reactive power based on the voltage amplitude. In the case when PV inverters failed to normalize the grid voltage, OLTC tap controller is used as an alternative. In this case, the tap of OLTC tap controller will change accordingly based on the maximum and minimum voltage estimated from phasor measurement unit (PMU) placed at key nodes in the grid. The validity of the voltage control system proposed in this paper is verified by detailed simulation and solid results.\",\"PeriodicalId\":356367,\"journal\":{\"name\":\"2018 3rd International Conference on Intelligent Green Building and Smart Grid (IGBSG)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 3rd International Conference on Intelligent Green Building and Smart Grid (IGBSG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IGBSG.2018.8393571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 3rd International Conference on Intelligent Green Building and Smart Grid (IGBSG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IGBSG.2018.8393571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

针对高渗透分布式光伏发电系统接入配电网后出现的电压限制问题,提出了一种由并网光伏逆变器和有载分接变压器组成的电压控制系统。光伏逆变器作为电网电压控制系统的一部分,可以根据电压幅值对无功功率进行控制。当光伏逆变器无法对电网电压进行归一化时,采用OLTC分接控制器作为替代方案。在这种情况下,OLTC分接控制器的分接将根据放置在电网关键节点的相量测量单元(PMU)估计的最大和最小电压相应地变化。通过详细的仿真和实测结果验证了本文所提出的电压控制系统的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Voltage control of distribution network with photovoltaic power generation systems
A voltage control system composed of grid-connected photovoltaic (PV) inverters and on-load tap changing transformer (OLTC) is proposed to solve the voltage limit problem arisen from high-penetration distributed PV power generation system integrated into the distribution network. PV inverters, as a part of grid voltage control system, are able to control the reactive power based on the voltage amplitude. In the case when PV inverters failed to normalize the grid voltage, OLTC tap controller is used as an alternative. In this case, the tap of OLTC tap controller will change accordingly based on the maximum and minimum voltage estimated from phasor measurement unit (PMU) placed at key nodes in the grid. The validity of the voltage control system proposed in this paper is verified by detailed simulation and solid results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance testing of NoSQL and RDBMS for storing big data in e-applications A high-power laser diode driver in vehicle headlight application Application of wavelet analysis theory in the switch cabinet arc protection system New hybrid control for wide input full-bridge LLC resonant DC/DC converter Simulations of network bottlenecks in smart grids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1