{"title":"雅典娜X-IFU检测链设计","authors":"H. Geoffray, B. Jackson, S. Bandler, S. Smith, W. Doriese, M. Durkin, J. van der Kuur, B. van Leeuwen, M. Kirivanta, D. PRELE, L. Ravera, Y. Parot, H. V. van Weers, J. D. den Herder, Joseph Adams, J. Chervenak, C. Reintsema, J. Ullom, F. Brachet, A. Ledot, P. Peille, D. Barret","doi":"10.1117/12.2629960","DOIUrl":null,"url":null,"abstract":"The x-ray integral field unit (X-IFU) instrument is the high-resolution x-ray spectrometer of the ESA Athena x-ray observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV from 5\" pixels, with a hexagonal field of view of 5' equivalent diameter. The main sensor array and its associated detection chain is one of the major sub-systems of the X-IFU instrument, and is the main contributor to X-IFU’s performance. CNES (the French Space Agency) is leading the development of X-IFU; additional major partners are NASA-GFSC, SRON, VTT, APC, NIST, and IRAP. This paper updates the B-phase definition of the X-IFU detection chain. The readout is based on time-division multiplexing (TDM). The different sub-components of the detection chain (the main sensor array, the cold electronics stages, and the warm electronics) require global design optimization in order to achieve the best performance. The detection chain’s sensitivity to the EMI/EMC environment requires detailed analysis and implementation of dedicated design solutions. This paper focuses on these aspects while providing an update to the detection-chain design description.","PeriodicalId":137463,"journal":{"name":"Astronomical Telescopes + Instrumentation","volume":"104 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design of the detection chain for Athena X-IFU\",\"authors\":\"H. Geoffray, B. Jackson, S. Bandler, S. Smith, W. Doriese, M. Durkin, J. van der Kuur, B. van Leeuwen, M. Kirivanta, D. PRELE, L. Ravera, Y. Parot, H. V. van Weers, J. D. den Herder, Joseph Adams, J. Chervenak, C. Reintsema, J. Ullom, F. Brachet, A. Ledot, P. Peille, D. Barret\",\"doi\":\"10.1117/12.2629960\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The x-ray integral field unit (X-IFU) instrument is the high-resolution x-ray spectrometer of the ESA Athena x-ray observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV from 5\\\" pixels, with a hexagonal field of view of 5' equivalent diameter. The main sensor array and its associated detection chain is one of the major sub-systems of the X-IFU instrument, and is the main contributor to X-IFU’s performance. CNES (the French Space Agency) is leading the development of X-IFU; additional major partners are NASA-GFSC, SRON, VTT, APC, NIST, and IRAP. This paper updates the B-phase definition of the X-IFU detection chain. The readout is based on time-division multiplexing (TDM). The different sub-components of the detection chain (the main sensor array, the cold electronics stages, and the warm electronics) require global design optimization in order to achieve the best performance. The detection chain’s sensitivity to the EMI/EMC environment requires detailed analysis and implementation of dedicated design solutions. This paper focuses on these aspects while providing an update to the detection-chain design description.\",\"PeriodicalId\":137463,\"journal\":{\"name\":\"Astronomical Telescopes + Instrumentation\",\"volume\":\"104 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Astronomical Telescopes + Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2629960\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Astronomical Telescopes + Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2629960","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

x射线积分场单元(X-IFU)仪器是ESA雅典娜x射线天文台的高分辨率x射线光谱仪。X-IFU将提供0.2至12 keV的光谱,光谱分辨率为2.5 eV,从5英寸像素到7 keV,具有5'等效直径的六角形视场。主传感器阵列及其相关的检测链是X-IFU仪器的主要子系统之一,是X-IFU仪器性能的主要贡献者。法国航天局(CNES)正在领导X-IFU的开发;其他主要合作伙伴包括NASA-GFSC、SRON、VTT、APC、NIST和IRAP。本文更新了X-IFU检测链的b相定义。读出基于时分多路复用(TDM)。检测链的不同子组件(主传感器阵列、冷电子级和热电子级)需要全局设计优化,以实现最佳性能。检测链对EMI/EMC环境的敏感性需要详细分析和实施专用设计解决方案。本文着重于这些方面,同时对检测链设计描述进行了更新。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of the detection chain for Athena X-IFU
The x-ray integral field unit (X-IFU) instrument is the high-resolution x-ray spectrometer of the ESA Athena x-ray observatory. X-IFU will deliver spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV from 5" pixels, with a hexagonal field of view of 5' equivalent diameter. The main sensor array and its associated detection chain is one of the major sub-systems of the X-IFU instrument, and is the main contributor to X-IFU’s performance. CNES (the French Space Agency) is leading the development of X-IFU; additional major partners are NASA-GFSC, SRON, VTT, APC, NIST, and IRAP. This paper updates the B-phase definition of the X-IFU detection chain. The readout is based on time-division multiplexing (TDM). The different sub-components of the detection chain (the main sensor array, the cold electronics stages, and the warm electronics) require global design optimization in order to achieve the best performance. The detection chain’s sensitivity to the EMI/EMC environment requires detailed analysis and implementation of dedicated design solutions. This paper focuses on these aspects while providing an update to the detection-chain design description.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
MARVEL: optical fiber link Development of a laser projection system for the ELT Commissioning a laser metrology truss for active optics on the Large Binocular Telescope SMATT, a tool that measures the mechanical loads on the support points of the TMT primary mirror supports Enhanced X-ray Timing and Polarimetry mission: eXTP: an update on its scientific cases, mission profile and development status
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1