阿尔斯通气化炉装置的减少订单控制器

A. Yousefi, B. Lohmann
{"title":"阿尔斯通气化炉装置的减少订单控制器","authors":"A. Yousefi, B. Lohmann","doi":"10.1109/MED.2006.328853","DOIUrl":null,"url":null,"abstract":"This paper presents a reduced order controller design approach for the Alstom benchmark, which drastically improves the simplicity and reduces the computation effort of the controller algorithm. As the gasifier process is complex with a high degree of cross coupling of the variables, designing a good controller is difficult. The use of optimal control method allows the simultaneous tuning a controller and seeking a tradeoff between the different performance objectives. But it results in a high order controller, which is not in practice desirable. Therefore in this paper, the full order observer is replaced with a reduced one and the state feedback is recalculated such that it guarantees the stability and recovers the performance. This idea can be regarded independent of the case study as a new method for designing a low order controller for high order plants","PeriodicalId":347035,"journal":{"name":"2006 14th Mediterranean Conference on Control and Automation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2006-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduced Order Controller for The Alstom Gasifier Plant\",\"authors\":\"A. Yousefi, B. Lohmann\",\"doi\":\"10.1109/MED.2006.328853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a reduced order controller design approach for the Alstom benchmark, which drastically improves the simplicity and reduces the computation effort of the controller algorithm. As the gasifier process is complex with a high degree of cross coupling of the variables, designing a good controller is difficult. The use of optimal control method allows the simultaneous tuning a controller and seeking a tradeoff between the different performance objectives. But it results in a high order controller, which is not in practice desirable. Therefore in this paper, the full order observer is replaced with a reduced one and the state feedback is recalculated such that it guarantees the stability and recovers the performance. This idea can be regarded independent of the case study as a new method for designing a low order controller for high order plants\",\"PeriodicalId\":347035,\"journal\":{\"name\":\"2006 14th Mediterranean Conference on Control and Automation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 14th Mediterranean Conference on Control and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MED.2006.328853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 14th Mediterranean Conference on Control and Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MED.2006.328853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种针对Alstom基准的降阶控制器设计方法,大大提高了控制器算法的简洁性,减少了计算量。由于气化炉过程复杂,各变量间交叉耦合程度高,设计一个好的控制器是困难的。最优控制方法的使用允许同时调整控制器并寻求不同性能目标之间的权衡。但它会导致高阶控制器,这在实践中是不可取的。因此,本文将全阶观测器替换为降阶观测器,并重新计算状态反馈,以保证系统的稳定性并恢复系统的性能。这种思想可以看作是独立于实例研究的一种设计高阶对象低阶控制器的新方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reduced Order Controller for The Alstom Gasifier Plant
This paper presents a reduced order controller design approach for the Alstom benchmark, which drastically improves the simplicity and reduces the computation effort of the controller algorithm. As the gasifier process is complex with a high degree of cross coupling of the variables, designing a good controller is difficult. The use of optimal control method allows the simultaneous tuning a controller and seeking a tradeoff between the different performance objectives. But it results in a high order controller, which is not in practice desirable. Therefore in this paper, the full order observer is replaced with a reduced one and the state feedback is recalculated such that it guarantees the stability and recovers the performance. This idea can be regarded independent of the case study as a new method for designing a low order controller for high order plants
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A note on Monotone Systems with Positive Translation Invariance Recent Advances on Linear Control Theory under Communication Constraints: A Survey Optimal path and tracking control of an autonomous VTOL aircraft A Finite Time Unknown Input Observer For Linear Systems Modelling and design of the half-bridge resonant inverter for induction cooking application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1