{"title":"三相异步电机在线效率诊断方法","authors":"J. Bacher","doi":"10.1109/POWERENG.2009.4915247","DOIUrl":null,"url":null,"abstract":"There are various methods to determine the efficiency of three phase induction machines. But all of them have in common that they are to inaccurate or they are impracticable. In this paper the machine efficiency will be derived from start up data. For that purpose the variation with time of all stator currents and all stator voltages have to been measured. Normally it isn't possible to mount a speed sensor on the machine. For this reason only the speed at the end of the start up can be determined. Practical results with standard three phase induction machines with different power ranges from 3 kW up to 500 kW are presented.","PeriodicalId":246039,"journal":{"name":"2009 International Conference on Power Engineering, Energy and Electrical Drives","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Online efficiency diagnostic method of three phase asynchronous machines\",\"authors\":\"J. Bacher\",\"doi\":\"10.1109/POWERENG.2009.4915247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are various methods to determine the efficiency of three phase induction machines. But all of them have in common that they are to inaccurate or they are impracticable. In this paper the machine efficiency will be derived from start up data. For that purpose the variation with time of all stator currents and all stator voltages have to been measured. Normally it isn't possible to mount a speed sensor on the machine. For this reason only the speed at the end of the start up can be determined. Practical results with standard three phase induction machines with different power ranges from 3 kW up to 500 kW are presented.\",\"PeriodicalId\":246039,\"journal\":{\"name\":\"2009 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2009.4915247\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2009.4915247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Online efficiency diagnostic method of three phase asynchronous machines
There are various methods to determine the efficiency of three phase induction machines. But all of them have in common that they are to inaccurate or they are impracticable. In this paper the machine efficiency will be derived from start up data. For that purpose the variation with time of all stator currents and all stator voltages have to been measured. Normally it isn't possible to mount a speed sensor on the machine. For this reason only the speed at the end of the start up can be determined. Practical results with standard three phase induction machines with different power ranges from 3 kW up to 500 kW are presented.