双三相永磁同步电动机谐波闭环模型预测容错控制

Pub Date : 2023-09-01 DOI:10.1360/sst-2022-0319
Jia CUI, WenXiang ZHAO, Tao TAO, LinSen HUANG, XianQun QIU
{"title":"双三相永磁同步电动机谐波闭环模型预测容错控制","authors":"Jia CUI, WenXiang ZHAO, Tao TAO, LinSen HUANG, XianQun QIU","doi":"10.1360/sst-2022-0319","DOIUrl":null,"url":null,"abstract":"The harmonic plane is coupled with the fundamental plane for the open-circuit-fault dual three-phase permanent magnet synchronous motor (DTP-PMSM). The conventional closed-loop control in the harmonic plane caused controller conflicts owing to this coupling effect, which reduced the fault-tolerant performance of the DTP-PMSM. Thus, this paper proposes a harmonic closed-loop fault-tolerant control strategy of DTP-PMSM without controller conflict for single-phase open-circuit faults. First, a fault-tolerant prediction model is derived using a dimensionality-reduced decoupling matrix to overcome the coupling effect, and then, a set of virtual voltage vector control sets suitable for open-circuit faults is reconstructed. In addition, a harmonic voltage extended-state observer is designed to suppress the harmonic current caused by nonlinear factors. The duty cycle that needs to be compensated is quickly obtained via coordinate transformation and injected into the corrected voltage vector to complete the harmonic closed-loop control. The experimental results demonstrate the feasibility and effectiveness of the proposed method.","PeriodicalId":69469,"journal":{"name":"","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Harmonic closed-loop model predictive fault-tolerant control of a dual three-phase permanent magnet synchronous motor\",\"authors\":\"Jia CUI, WenXiang ZHAO, Tao TAO, LinSen HUANG, XianQun QIU\",\"doi\":\"10.1360/sst-2022-0319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The harmonic plane is coupled with the fundamental plane for the open-circuit-fault dual three-phase permanent magnet synchronous motor (DTP-PMSM). The conventional closed-loop control in the harmonic plane caused controller conflicts owing to this coupling effect, which reduced the fault-tolerant performance of the DTP-PMSM. Thus, this paper proposes a harmonic closed-loop fault-tolerant control strategy of DTP-PMSM without controller conflict for single-phase open-circuit faults. First, a fault-tolerant prediction model is derived using a dimensionality-reduced decoupling matrix to overcome the coupling effect, and then, a set of virtual voltage vector control sets suitable for open-circuit faults is reconstructed. In addition, a harmonic voltage extended-state observer is designed to suppress the harmonic current caused by nonlinear factors. The duty cycle that needs to be compensated is quickly obtained via coordinate transformation and injected into the corrected voltage vector to complete the harmonic closed-loop control. The experimental results demonstrate the feasibility and effectiveness of the proposed method.\",\"PeriodicalId\":69469,\"journal\":{\"name\":\"\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1360/sst-2022-0319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1360/sst-2022-0319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Harmonic closed-loop model predictive fault-tolerant control of a dual three-phase permanent magnet synchronous motor
The harmonic plane is coupled with the fundamental plane for the open-circuit-fault dual three-phase permanent magnet synchronous motor (DTP-PMSM). The conventional closed-loop control in the harmonic plane caused controller conflicts owing to this coupling effect, which reduced the fault-tolerant performance of the DTP-PMSM. Thus, this paper proposes a harmonic closed-loop fault-tolerant control strategy of DTP-PMSM without controller conflict for single-phase open-circuit faults. First, a fault-tolerant prediction model is derived using a dimensionality-reduced decoupling matrix to overcome the coupling effect, and then, a set of virtual voltage vector control sets suitable for open-circuit faults is reconstructed. In addition, a harmonic voltage extended-state observer is designed to suppress the harmonic current caused by nonlinear factors. The duty cycle that needs to be compensated is quickly obtained via coordinate transformation and injected into the corrected voltage vector to complete the harmonic closed-loop control. The experimental results demonstrate the feasibility and effectiveness of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1