一种用于生命体征监测设备的三波段贴片天线仿真模型

Q4 Biochemistry, Genetics and Molecular Biology Journal of Biomolecular Techniques Pub Date : 2023-09-03 DOI:10.51173/jt.v5i3.1221
None Anfal Shukur Taher, None Rashid Ali Fayadh, None Abbas Fadhal Humadi, None Aaraf Shukur Alqaisi, None Mohd Fareq Abd Malek
{"title":"一种用于生命体征监测设备的三波段贴片天线仿真模型","authors":"None Anfal Shukur Taher, None Rashid Ali Fayadh, None Abbas Fadhal Humadi, None Aaraf Shukur Alqaisi, None Mohd Fareq Abd Malek","doi":"10.51173/jt.v5i3.1221","DOIUrl":null,"url":null,"abstract":"In the modern lifestyle, an increase in psychological pressures was observed, leading to an increase in various diseases, which increased the need for diagnosis and treatment, (i.e., increased demand for) equipment to monitor vital activities, Therefore, a microstrip patch antenna was suggested as the topic of this article because it is popular in wireless systems due to its low cost, lightweight, and thin profile. The proposed design is made of FR-4 as a substrate material, and copper for the patch and the ground. The reader can notice that our proposed antenna owns the following resonance frequencies: (3.68), (6.48), and (7.93) GHz respectively. The gain values for the previous resonance frequencies were respectively (27) dBi, (11.1) dBi, and (4.19) dBi, while the values of directivity were (32.17) dBi, (15.70) dBi, and (7.984) dBi. The radiation efficiency values were (-5.179) dB, (-4.561) dB, and (-3.789) dB, while the values of the total efficiency were (-5.207) dB, (-4.631) dB, and (-3.799) dB The operating bandwidths were: (0.1146) GHz, (0.2764) GHz, and (0.3641) GHz. The design was simulated with CST software.","PeriodicalId":39617,"journal":{"name":"Journal of Biomolecular Techniques","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Simulated Model of a Triple Band Patch Antenna Proposed for Vital Signs Monitoring Equipment\",\"authors\":\"None Anfal Shukur Taher, None Rashid Ali Fayadh, None Abbas Fadhal Humadi, None Aaraf Shukur Alqaisi, None Mohd Fareq Abd Malek\",\"doi\":\"10.51173/jt.v5i3.1221\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the modern lifestyle, an increase in psychological pressures was observed, leading to an increase in various diseases, which increased the need for diagnosis and treatment, (i.e., increased demand for) equipment to monitor vital activities, Therefore, a microstrip patch antenna was suggested as the topic of this article because it is popular in wireless systems due to its low cost, lightweight, and thin profile. The proposed design is made of FR-4 as a substrate material, and copper for the patch and the ground. The reader can notice that our proposed antenna owns the following resonance frequencies: (3.68), (6.48), and (7.93) GHz respectively. The gain values for the previous resonance frequencies were respectively (27) dBi, (11.1) dBi, and (4.19) dBi, while the values of directivity were (32.17) dBi, (15.70) dBi, and (7.984) dBi. The radiation efficiency values were (-5.179) dB, (-4.561) dB, and (-3.789) dB, while the values of the total efficiency were (-5.207) dB, (-4.631) dB, and (-3.799) dB The operating bandwidths were: (0.1146) GHz, (0.2764) GHz, and (0.3641) GHz. The design was simulated with CST software.\",\"PeriodicalId\":39617,\"journal\":{\"name\":\"Journal of Biomolecular Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomolecular Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51173/jt.v5i3.1221\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomolecular Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51173/jt.v5i3.1221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

在现代生活方式中,人们观察到心理压力的增加,导致各种疾病的增加,这增加了对诊断和治疗的需求,即对监测生命活动的设备的需求增加。因此,微带贴片天线被建议作为本文的主题,因为它在无线系统中很受欢迎,因为它成本低,重量轻,外形薄。提出的设计是由FR-4作为衬底材料,铜作为贴片和接地。读者可以注意到,我们提出的天线的谐振频率分别为(3.68)GHz、(6.48)GHz和(7.93)GHz。谐振频率的增益值分别为(27)dBi、(11.1)dBi和(4.19)dBi,指向性值分别为(32.17)dBi、(15.70)dBi和(7.984)dBi。辐射效率值分别为(-5.179)dB、(-4.561)dB和(-3.789)dB,总效率值分别为(-5.207)dB、(-4.631)dB和(-3.799)dB,工作带宽分别为(0.1146)GHz、(0.2764)GHz和(0.3641)GHz。采用CST软件对设计进行了仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Simulated Model of a Triple Band Patch Antenna Proposed for Vital Signs Monitoring Equipment
In the modern lifestyle, an increase in psychological pressures was observed, leading to an increase in various diseases, which increased the need for diagnosis and treatment, (i.e., increased demand for) equipment to monitor vital activities, Therefore, a microstrip patch antenna was suggested as the topic of this article because it is popular in wireless systems due to its low cost, lightweight, and thin profile. The proposed design is made of FR-4 as a substrate material, and copper for the patch and the ground. The reader can notice that our proposed antenna owns the following resonance frequencies: (3.68), (6.48), and (7.93) GHz respectively. The gain values for the previous resonance frequencies were respectively (27) dBi, (11.1) dBi, and (4.19) dBi, while the values of directivity were (32.17) dBi, (15.70) dBi, and (7.984) dBi. The radiation efficiency values were (-5.179) dB, (-4.561) dB, and (-3.789) dB, while the values of the total efficiency were (-5.207) dB, (-4.631) dB, and (-3.799) dB The operating bandwidths were: (0.1146) GHz, (0.2764) GHz, and (0.3641) GHz. The design was simulated with CST software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Biomolecular Techniques
Journal of Biomolecular Techniques Biochemistry, Genetics and Molecular Biology-Molecular Biology
CiteScore
2.50
自引率
0.00%
发文量
9
期刊介绍: The Journal of Biomolecular Techniques is a peer-reviewed publication issued five times a year by the Association of Biomolecular Resource Facilities. The Journal was established to promote the central role biotechnology plays in contemporary research activities, to disseminate information among biomolecular resource facilities, and to communicate the biotechnology research conducted by the Association’s Research Groups and members, as well as other investigators.
期刊最新文献
Effect of Different Polishing Systems on Surface Roughness of IPS Empress Ceramic Materials Evaluation of the Effect of Nano and Micro Hydroxyapatite Particles on the Impact Strength of Acrylic Resin: In Vitro Study The Effect of Recycled CAD/CAM PEEK Fibers on the Transverse Strength of Repaired Acrylic Resin Assessment of Vitamin D3 Level Among a Sample of Type 2 Diabetic Patients Attending Diabetes and Endocrinology Center in Al-Hilla City The Impact of Digital Transformation in Enhancing Operational Performance: An Applied Study in the Kirkuk Electricity Distribution Branch
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1