{"title":"口腔切开术和XP-endo整形术在牙本质去除量上的体外比较:一项显微计算机断层研究","authors":"Elaf A Rehan, Radwa S Emara, Geraldine M Ahmed","doi":"10.54905/disssi/v27i138/e322ms3143","DOIUrl":null,"url":null,"abstract":"Objective: To use micro-computed tomography to assess the effectiveness of the TruNatomy versus the XP-endo Shaper for removing dentin from single-rooted permanent teeth with straight root canals. Materials and Methods: Ninety-eight extracted human single-root teeth were collected and divided into two equal groups: TruNatomy and XP-endo Shaper (XPS). Root canal instrumentation was done for each system. Pre-and post-instrumentation images were scanned by using Skyscan 1172 micro-CT scanner at a resolution of 13.73 µm to measure dentin removal, differences in dentin thickness, and percent change in root canal volume. The data were analyzed using SPSS. Results: The TruNatomy group and XP-endo Shaper had no significant difference regarding the amount of removed dentin. Conclusion: There was no significant difference in post-instrumentation canal volume and dentine removal between TruNatomy and XP-endo Shaper. Thus, both file systems are equally recommended for clinical use as a practice of minimally invasive endodontics.","PeriodicalId":18393,"journal":{"name":"Medical Science","volume":"5 1","pages":"0"},"PeriodicalIF":0.5000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-vitro comparison of TruNatomy and XP-endo Shaper on amount of dentin removal: A micro-computed tomography study\",\"authors\":\"Elaf A Rehan, Radwa S Emara, Geraldine M Ahmed\",\"doi\":\"10.54905/disssi/v27i138/e322ms3143\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To use micro-computed tomography to assess the effectiveness of the TruNatomy versus the XP-endo Shaper for removing dentin from single-rooted permanent teeth with straight root canals. Materials and Methods: Ninety-eight extracted human single-root teeth were collected and divided into two equal groups: TruNatomy and XP-endo Shaper (XPS). Root canal instrumentation was done for each system. Pre-and post-instrumentation images were scanned by using Skyscan 1172 micro-CT scanner at a resolution of 13.73 µm to measure dentin removal, differences in dentin thickness, and percent change in root canal volume. The data were analyzed using SPSS. Results: The TruNatomy group and XP-endo Shaper had no significant difference regarding the amount of removed dentin. Conclusion: There was no significant difference in post-instrumentation canal volume and dentine removal between TruNatomy and XP-endo Shaper. Thus, both file systems are equally recommended for clinical use as a practice of minimally invasive endodontics.\",\"PeriodicalId\":18393,\"journal\":{\"name\":\"Medical Science\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54905/disssi/v27i138/e322ms3143\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54905/disssi/v27i138/e322ms3143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In-vitro comparison of TruNatomy and XP-endo Shaper on amount of dentin removal: A micro-computed tomography study
Objective: To use micro-computed tomography to assess the effectiveness of the TruNatomy versus the XP-endo Shaper for removing dentin from single-rooted permanent teeth with straight root canals. Materials and Methods: Ninety-eight extracted human single-root teeth were collected and divided into two equal groups: TruNatomy and XP-endo Shaper (XPS). Root canal instrumentation was done for each system. Pre-and post-instrumentation images were scanned by using Skyscan 1172 micro-CT scanner at a resolution of 13.73 µm to measure dentin removal, differences in dentin thickness, and percent change in root canal volume. The data were analyzed using SPSS. Results: The TruNatomy group and XP-endo Shaper had no significant difference regarding the amount of removed dentin. Conclusion: There was no significant difference in post-instrumentation canal volume and dentine removal between TruNatomy and XP-endo Shaper. Thus, both file systems are equally recommended for clinical use as a practice of minimally invasive endodontics.