Alexei A. Korobko
{"title":"公路隧道照度计算方法","authors":"Alexei A. Korobko","doi":"10.33383/2022-075","DOIUrl":null,"url":null,"abstract":"The study proposes a method of electrical lighting calculation for a road tunnel, which allows estimating locations of selected luminaires providing the required road surface luminance distribution in the areas of vehicle driver adaptation while driving through a tunnel during daytime. The method is based on the adopted concepts of saturation curve and luminance saturation zone which are used for building of a step curve approximating the set zonal distribution of luminance. The basic terms of the method and the calculation algorithm as well as an example of calculation of luminaire locations in the tunnel luminance zones illustrated by comparison of estimated and pre-set luminance distributions are presented.","PeriodicalId":49907,"journal":{"name":"Light & Engineering","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Method of Calculation of a Road Tunnel Illumination\",\"authors\":\"Alexei A. Korobko\",\"doi\":\"10.33383/2022-075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study proposes a method of electrical lighting calculation for a road tunnel, which allows estimating locations of selected luminaires providing the required road surface luminance distribution in the areas of vehicle driver adaptation while driving through a tunnel during daytime. The method is based on the adopted concepts of saturation curve and luminance saturation zone which are used for building of a step curve approximating the set zonal distribution of luminance. The basic terms of the method and the calculation algorithm as well as an example of calculation of luminaire locations in the tunnel luminance zones illustrated by comparison of estimated and pre-set luminance distributions are presented.\",\"PeriodicalId\":49907,\"journal\":{\"name\":\"Light & Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Light & Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33383/2022-075\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Light & Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33383/2022-075","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

本研究提出了一种道路隧道的电气照明计算方法,该方法可以在车辆驾驶员适应区域内提供所需的路面亮度分布,从而估算出选定灯具的位置。该方法采用了饱和度曲线和亮度饱和区的概念,利用这两个概念建立了近似于设定的亮度区域分布的阶跃曲线。给出了该方法的基本术语和计算算法,并通过估算和预置亮度分布的比较,给出了隧道照明区域内灯具位置的计算实例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Method of Calculation of a Road Tunnel Illumination
The study proposes a method of electrical lighting calculation for a road tunnel, which allows estimating locations of selected luminaires providing the required road surface luminance distribution in the areas of vehicle driver adaptation while driving through a tunnel during daytime. The method is based on the adopted concepts of saturation curve and luminance saturation zone which are used for building of a step curve approximating the set zonal distribution of luminance. The basic terms of the method and the calculation algorithm as well as an example of calculation of luminaire locations in the tunnel luminance zones illustrated by comparison of estimated and pre-set luminance distributions are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Light & Engineering
Light & Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-OPTICS
CiteScore
1.00
自引率
50.00%
发文量
0
审稿时长
1 months
期刊介绍: Our magazine develops comprehensive communication within the lighting community, providing opportunities for discussion and free expression of opinions of specialists of different profiles; contributes to the convergence of science and engineering practice, the search for opportunities for the application of research results in lighting and technological applications of light; keeps the scientific community up to date with the latest advances in the theory of the light field, providing readers with operational professional information; initiates international cooperation, promotes and distributes the results of Russian authors in the international professional community; provides equal opportunities for authors from different regions of Russia and other countries. The journal publishes articles in the following areas: visual and non-visual effects of radiation on humans; light field theory; photometry and colorimetry; sources of light; ballasts; light devices, their design and production technology; lighting and irradiation installation; light signaling; methods of mathematical modeling of light devices and installations; problems of energy saving in lighting, installation and operation of lighting installations; modern production technologies of lighting products for lighting control systems; innovative design solutions; innovations in lighting and lighting design; the study of the effect on plants and animals, problems of using light in medicine; problems of disinfection of premises, water and smell elimination with the help of technology of UV radiation using; problems of light in the ocean and space.
期刊最新文献
Electrodeless Source of UV Radiation Based on Low-Pressure Microwave Mercury Discharge Choosing a Method for Approximating the Spectral Distribution of Colour LEDs and Comparing their Parameters and Characteristics in Nominal Mode Results of Research into Energy Parameters and Characteristics of LED Lamps Method of Calculation of a Road Tunnel Illumination About Efficiency of the Ultraviolet Diodes Applied for Disinfection of Water
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1