F. Mohammadbaghery, S. Saramad, M. Shamsaei, H. Rahimpour
{"title":"二维微边缘气体室(2D-MEGC)的制造与测试","authors":"F. Mohammadbaghery, S. Saramad, M. Shamsaei, H. Rahimpour","doi":"10.1016/j.nima.2023.168603","DOIUrl":null,"url":null,"abstract":"This work proposes using silver flat ribbon cable to fabricate a new type of position-sensitive gaseous detector. This structure consists of a thin conductive silver of flat ribbon cable (anodes) and thicker copper sheets (cathodes) separated by a plastic insulator. To fix the position of the anodes and the cathodes, a holder compressed the layers. The layers are cut from the edges and polished at several steps to have a smooth surface. These arrays of anodes and cathodes, created by the proposed method, act as a two-dimensional position-sensitive proportional detector. Applying a suitable voltage between the anodes and cathodes produces a strong electric field near the vicinity of the anodes. This electric field multiplies primary electrons generated by ionizing radiation. The experimental results show that for the proposed two Dimensional Micro Edge Gas Chamber (2D-MEGC), at HV1=350 with the gas mixture of (Ar 85% - CO2 15%), the maximum multiplication factor without electric discharge is around 250. All pixels were separately connected to the preamplifier-amplifier setup to test the position sensitivity of 2D-MEGC. As expected for a non-collimated alpha source, the maximum recorded interactions are related to the closest pixel to the radioactive source. The Raether limit is a good benchmark concerning the quality of fabricated gaseous detectors. In the best design conditions, this value for Micro Strip Gas Chamber (MSGCs) is 4 × 107. For the fabricated 2D-MEGC, this number is 2.5 × 107. This result shows that the proposed 2D-MEGC performs well despite its simple structure and fabrication.","PeriodicalId":19383,"journal":{"name":"Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fabrication and testing of two-dimensional Micro-Edge Gas Chamber (2D-MEGC)\",\"authors\":\"F. Mohammadbaghery, S. Saramad, M. Shamsaei, H. Rahimpour\",\"doi\":\"10.1016/j.nima.2023.168603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work proposes using silver flat ribbon cable to fabricate a new type of position-sensitive gaseous detector. This structure consists of a thin conductive silver of flat ribbon cable (anodes) and thicker copper sheets (cathodes) separated by a plastic insulator. To fix the position of the anodes and the cathodes, a holder compressed the layers. The layers are cut from the edges and polished at several steps to have a smooth surface. These arrays of anodes and cathodes, created by the proposed method, act as a two-dimensional position-sensitive proportional detector. Applying a suitable voltage between the anodes and cathodes produces a strong electric field near the vicinity of the anodes. This electric field multiplies primary electrons generated by ionizing radiation. The experimental results show that for the proposed two Dimensional Micro Edge Gas Chamber (2D-MEGC), at HV1=350 with the gas mixture of (Ar 85% - CO2 15%), the maximum multiplication factor without electric discharge is around 250. All pixels were separately connected to the preamplifier-amplifier setup to test the position sensitivity of 2D-MEGC. As expected for a non-collimated alpha source, the maximum recorded interactions are related to the closest pixel to the radioactive source. The Raether limit is a good benchmark concerning the quality of fabricated gaseous detectors. In the best design conditions, this value for Micro Strip Gas Chamber (MSGCs) is 4 × 107. For the fabricated 2D-MEGC, this number is 2.5 × 107. This result shows that the proposed 2D-MEGC performs well despite its simple structure and fabrication.\",\"PeriodicalId\":19383,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.nima.2023.168603\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.nima.2023.168603","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出用银扁带电缆制作一种新型位置敏感气体探测器。这种结构由一层薄的导电银带状电缆(阳极)和由塑料绝缘体隔开的较厚的铜片(阴极)组成。为了固定阳极和阴极的位置,一个支架压缩了这些层。这些层从边缘切割下来,并经过几个步骤抛光,以获得光滑的表面。这些阳极和阴极阵列,由提出的方法,作为一个二维位置敏感的比例探测器。在阳极和阴极之间施加合适的电压,在阳极附近产生一个强电场。这个电场使电离辐射产生的初级电子倍增。实验结果表明,对于所设计的二维微边缘气体室(2D-MEGC),在HV1=350,气体混合物为(Ar 85% - CO2 15%)时,不放电时的最大倍增系数约为250。所有像素分别连接到前置放大器-放大器设置,以测试2D-MEGC的位置灵敏度。对于非准直的α源,最大记录的相互作用与最接近放射源的像素有关。以太极限是衡量气体探测器质量的一个很好的基准。在最佳设计条件下,微带毒气室(msgc)的该值为4 × 107。对于制作的2D-MEGC,该数字为2.5 × 107。结果表明,所提出的2D-MEGC结构简单,制作简单,但性能良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fabrication and testing of two-dimensional Micro-Edge Gas Chamber (2D-MEGC)
This work proposes using silver flat ribbon cable to fabricate a new type of position-sensitive gaseous detector. This structure consists of a thin conductive silver of flat ribbon cable (anodes) and thicker copper sheets (cathodes) separated by a plastic insulator. To fix the position of the anodes and the cathodes, a holder compressed the layers. The layers are cut from the edges and polished at several steps to have a smooth surface. These arrays of anodes and cathodes, created by the proposed method, act as a two-dimensional position-sensitive proportional detector. Applying a suitable voltage between the anodes and cathodes produces a strong electric field near the vicinity of the anodes. This electric field multiplies primary electrons generated by ionizing radiation. The experimental results show that for the proposed two Dimensional Micro Edge Gas Chamber (2D-MEGC), at HV1=350 with the gas mixture of (Ar 85% - CO2 15%), the maximum multiplication factor without electric discharge is around 250. All pixels were separately connected to the preamplifier-amplifier setup to test the position sensitivity of 2D-MEGC. As expected for a non-collimated alpha source, the maximum recorded interactions are related to the closest pixel to the radioactive source. The Raether limit is a good benchmark concerning the quality of fabricated gaseous detectors. In the best design conditions, this value for Micro Strip Gas Chamber (MSGCs) is 4 × 107. For the fabricated 2D-MEGC, this number is 2.5 × 107. This result shows that the proposed 2D-MEGC performs well despite its simple structure and fabrication.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterizing Modulation Transform Functions for varying Zeff materials Evaluation of the X-ray SOI pixel detector with the on-chip ADC The future of bent MAPS, full-wafer (stitched) design: Status and challenges Radiation tolerance test and performance verification of pnCCD at high temperatures for future satellite mission HiZ-GUNDAM ANALYSIS OF THE QUALITY ASSURANCE RESULTS FROM THE INITIAL PART OF PRODUCTION OF THE ATLAS18 ITK STRIP SENSORS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1