Eky Susilowati, Fatma Lestari
{"title":"东雅加达某制药业危险区域分类评价","authors":"Eky Susilowati, Fatma Lestari","doi":"10.20473/ijosh.v12i1si.2023.1-11","DOIUrl":null,"url":null,"abstract":"Introduction: Fire is a common risk in any industrial facility that uses combustible and flammable raw materials, products, or supporting materials. Among others, the pharmaceutical industry is exposed to such risk due to the application of flammable liquids including ethanol as a volatile solvent in production areas, which has the potential to form explosive atmospheres through evaporation from pools created by accidental releases. Therefore, this study aims to analyze the hazardous area classification (HAC) in ethanol storage areas to facilitate the execution of risk mitigation efforts for reducing the role of ignition sources that cause fire and explosion. Methods: The HAC assessment was carried out in December 2021 - January 2022 using the quantitative method outlined in the International Electrotechnical Commission (IEC) standard: IEC/EN 60079-10-1 for zone determination. During flash point analysis, the ASTM D-93 method was employed to define the class of ethanol as a flammable liquid. Results: The ethanol storage areas fell into the zone 2 category based on the secondary grade of release, as well as the areas’ ventilation effectiveness with a medium dilution, and fair ventilation availability. The extent of zone 2 is up to 3 m from the release source. Conclusion: Ignition sources capable of leading to fire and explosion incidents in ethanol storage areas should be controlled.","PeriodicalId":33133,"journal":{"name":"The Indonesian Journal of Occupational Safety and Health","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hazardous Area Classification Assessment at a Pharmaceutical Industry in East Jakarta\",\"authors\":\"Eky Susilowati, Fatma Lestari\",\"doi\":\"10.20473/ijosh.v12i1si.2023.1-11\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Fire is a common risk in any industrial facility that uses combustible and flammable raw materials, products, or supporting materials. Among others, the pharmaceutical industry is exposed to such risk due to the application of flammable liquids including ethanol as a volatile solvent in production areas, which has the potential to form explosive atmospheres through evaporation from pools created by accidental releases. Therefore, this study aims to analyze the hazardous area classification (HAC) in ethanol storage areas to facilitate the execution of risk mitigation efforts for reducing the role of ignition sources that cause fire and explosion. Methods: The HAC assessment was carried out in December 2021 - January 2022 using the quantitative method outlined in the International Electrotechnical Commission (IEC) standard: IEC/EN 60079-10-1 for zone determination. During flash point analysis, the ASTM D-93 method was employed to define the class of ethanol as a flammable liquid. Results: The ethanol storage areas fell into the zone 2 category based on the secondary grade of release, as well as the areas’ ventilation effectiveness with a medium dilution, and fair ventilation availability. The extent of zone 2 is up to 3 m from the release source. Conclusion: Ignition sources capable of leading to fire and explosion incidents in ethanol storage areas should be controlled.\",\"PeriodicalId\":33133,\"journal\":{\"name\":\"The Indonesian Journal of Occupational Safety and Health\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Indonesian Journal of Occupational Safety and Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20473/ijosh.v12i1si.2023.1-11\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Indonesian Journal of Occupational Safety and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/ijosh.v12i1si.2023.1-11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导言:火灾是任何使用可燃和易燃原料、产品或配套材料的工业设施的共同风险。除其他外,由于在生产区域使用易燃液体,包括乙醇作为挥发性溶剂,制药行业面临这种风险,这些液体有可能通过意外释放产生的池的蒸发形成爆炸性环境。因此,本研究旨在分析乙醇储存区的危险区域分类(HAC),以促进风险缓解工作的执行,以减少引起火灾和爆炸的点火源的作用。方法:采用国际电工委员会(IEC)标准IEC/EN 60079-10-1中概述的区域测定定量方法,于2021年12月至2022年1月进行HAC评估。在闪点分析中,采用ASTM D-93方法将乙醇的类别定义为易燃液体。结果:从二级释放度、中等稀释度的通风效果和良好的通风有效性来看,乙醇储存区属于2区。第2区距离释放源最多3米。结论:应控制乙醇储存区可能引起火灾和爆炸事件的火源。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hazardous Area Classification Assessment at a Pharmaceutical Industry in East Jakarta
Introduction: Fire is a common risk in any industrial facility that uses combustible and flammable raw materials, products, or supporting materials. Among others, the pharmaceutical industry is exposed to such risk due to the application of flammable liquids including ethanol as a volatile solvent in production areas, which has the potential to form explosive atmospheres through evaporation from pools created by accidental releases. Therefore, this study aims to analyze the hazardous area classification (HAC) in ethanol storage areas to facilitate the execution of risk mitigation efforts for reducing the role of ignition sources that cause fire and explosion. Methods: The HAC assessment was carried out in December 2021 - January 2022 using the quantitative method outlined in the International Electrotechnical Commission (IEC) standard: IEC/EN 60079-10-1 for zone determination. During flash point analysis, the ASTM D-93 method was employed to define the class of ethanol as a flammable liquid. Results: The ethanol storage areas fell into the zone 2 category based on the secondary grade of release, as well as the areas’ ventilation effectiveness with a medium dilution, and fair ventilation availability. The extent of zone 2 is up to 3 m from the release source. Conclusion: Ignition sources capable of leading to fire and explosion incidents in ethanol storage areas should be controlled.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
40
审稿时长
5 weeks
期刊最新文献
Proposed Workstation Design in Laboratory for Musculoskeletal Disorder Complaints The Paradox of Health and Safety Risks: A Disclose of Handling Strategies in Informal Construction Sites in Tanzania Implementation of Occupational Safety and Health Management System in the Education Sector The Effect of Work, Family Conflict, and Work Shifts on the Performance of Midwives with Work Stress as Intervening Variables Work Safety Aspects on the Sea on Small-Scale Fishermen in Jember Regency, Indonesia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1